Literature DB >> 15189526

Use of a sterile, disposable, radiation-absorbing shield reduces occupational exposure to scatter radiation during pectoral device implantation.

Grant R Simons1, William W Orrison.   

Abstract

The aim of this study was to demonstrate the effectiveness of a radiation-absorbing shield in reducing physicians' occupational radiation exposure during pectoral device implantation. A sterile, disposable, lead-free radiation-absorbing surgical drape containing x-ray attenuation material was evaluated. Twenty procedures used the radiation absorbing drape, and 20 were performed without the shielding. Radiation exposure was measured using thermoluminescent dosimetry collar badges. Use of the protective shield was associated with a time adjusted 80% reduction in radiation dose (0.009 mrem/s with shielding vs 0.047 mrem/s without shielding, P < 0.05) to the physician performing the procedures. The radiation-absorbing surgical drape did not interfere with technical performance nor add procedural time, and all procedures were successfully completed. This study demonstrates that a sterile, disposable, radiation-absorbing drape provides a convenient means of augmenting conventional radiation shielding. Use of this protective shielding greatly reduces operators' occupational exposure to scatter radiation during pectoral device implantation without compromising sterility or procedural technique.

Mesh:

Substances:

Year:  2004        PMID: 15189526     DOI: 10.1111/j.1540-8159.2004.00520.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  The Efficacy of Shielding Systems for Reducing Operator Exposure during Neurointerventional Procedures: A Real-World Prospective Study.

Authors:  T R Miller; J Zhuo; G Jindal; R Shivashankar; N Beaty; D Gandhi
Journal:  AJNR Am J Neuroradiol       Date:  2016-12-22       Impact factor: 3.825

2.  Novel paint design based on nanopowder to protection against X and gamma rays.

Authors:  Mohammad Mehdi Movahedi; Adibe Abdi; Alireza Mehdizadeh; Naser Dehghan; Emad Heidari; Yusef Masumi; Mojtaba Abbaszadeh
Journal:  Indian J Nucl Med       Date:  2014-01

Review 3.  The Growing Culture Of A Minimally Fluoroscopic Approach In Electrophysiology Lab.

Authors:  Michela Casella; Eleonora Russo; Francesca Pizzamiglio; Sergio Conti; Ghaliah Al-Mohani; Daniele Colombo; Victor Casula; Yuri D Alessandra; Viviana Biagioli; Corrado Carbucicchio; Stefania Riva; Gaetano Fassini; Massimo Moltrasio; Fabrizio Tundo; Martina Zucchetti; Benedetta Majocchi; Vittoria Marino; Giovanni Forleo; Pasquale Santangeli; Luigi Di Biase; Antonio Dello Russo; Andrea Natale; Claudio Tondo
Journal:  J Atr Fibrillation       Date:  2014-08-31

4.  A novel radiation protection device based on tungsten functional paper for application in interventional radiology.

Authors:  Hajime Monzen; Mikoto Tamura; Kohei Shimomura; Yuichi Onishi; Shinichi Nakayama; Takahiro Fujimoto; Kenji Matsumoto; Kohei Hanaoka; Takeshi Kamomae
Journal:  J Appl Clin Med Phys       Date:  2017-04-19       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.