Literature DB >> 15187744

Comparison of a sliding hip screw with a trochanteric lateral support plate to an intramedullary hip screw for fixation of unstable intertrochanteric hip fractures: a cadaver study.

Matthew R Bong1, Vipul Patel, Kazuho Iesaka, Kenneth A Egol, Frederick J Kummer, Kenneth J Koval.   

Abstract

BACKGROUND: The lateral trochanteric support plate (LSP) was developed to prevent excessive sliding of unstable intertrochanteric femur fractures fixed with a sliding hip screw (SHS). This study compared the fracture stability and screw sliding characteristics of unstable intertrochanteric femur fractures fixed with either an SHS and LSP or an Intramedullary Hip Screw (IMHS).
METHODS: Six matched pairs of cadaveric human femurs with simulated, unstable intertrochanteric femur fractures were stabilized with either an IMHS or a 135-degree SHS with an attached LSP. Inferior and lateral head displacements and lag screw sliding distances were measured for applied static loads of 750 N, before and after cycling.
RESULTS: Four-part unstable intertrochanteric femur fractures showed comparable screw sliding characteristics and stability whether instrumented with an SHS and LSP or an IMHS.
CONCLUSION: A sliding hip screw with an attached lateral support plate provides stability and ability to resist medial displacement of the femoral shaft similar to that seen with the IMHS.

Entities:  

Mesh:

Year:  2004        PMID: 15187744     DOI: 10.1097/01.ta.0000046265.44785.0c

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  12 in total

Review 1.  [Pertrochanteric femoral fractures in the elderly].

Authors:  G H Sandmann; P Biberthaler
Journal:  Unfallchirurg       Date:  2015-05       Impact factor: 1.000

2.  Screw-blade fixation systems in Pauwels three femoral neck fractures: a biomechanical evaluation.

Authors:  Matthias Knobe; Simon Altgassen; Klaus-Jürgen Maier; Gertraud Gradl-Dietsch; Chris Kaczmarek; Sven Nebelung; Kajetan Klos; Bong-Sung Kim; Boyko Gueorguiev; Klemens Horst; Benjamin Buecking
Journal:  Int Orthop       Date:  2017-08-06       Impact factor: 3.075

3.  Dynamic Hip Screw with Trochanteric Stablization Plate Fixation of Unstable Inter-Trochanteric Fractures: A Prospective Study of Functional and Radiological Outcomes.

Authors:  Ashwin Shetty; Arjun Ballal; Anand Kumar Sadasivan; Anoop Hegde
Journal:  J Clin Diagn Res       Date:  2016-09-01

4.  Which AO/OTA 31-A2 pertrochanteric fractures can be treated with a dynamic hip screw without developing a lateral wall fracture? A CT-based study.

Authors:  Gaurav Sharma; Ravijot Singh; Kiran Kumar Gn; Vaibhav Jain; Ankit Gupta; Shivanand Gamanagatti; Kamran Farooque; Vijay Sharma
Journal:  Int Orthop       Date:  2015-07-04       Impact factor: 3.075

Review 5.  [Trochanteric femoral fractures: anatomy, biomechanics and choice of implants].

Authors:  F Bonnaire; T Lein; P Bula
Journal:  Unfallchirurg       Date:  2011-06       Impact factor: 1.000

6.  [The rotationally stable screw-anchor with trochanteric stabilizing plate (RoSA/TSP) : First results in unstable trochanteric femur fractures].

Authors:  K-J Maier; B Bücking; K Horst; H Andruszkow; F Hildebrand; M Knobe
Journal:  Unfallchirurg       Date:  2017-12       Impact factor: 1.000

7.  Biomechanical Evaluation of Four Methods for Internal Fixation of Comminuted Subtrochanteric Fractures.

Authors:  Jie Wang; Jian-Xiong Ma; Hao-Bo Jia; Yang Chen; Yang Yang; Xin-Long Ma
Journal:  Medicine (Baltimore)       Date:  2016-05       Impact factor: 1.889

8.  Implants for trochanteric fractures in Norway: the role of the trochanteric stabilizing plate-a study on 20,902 fractures from the Norwegian hip fracture register 2011-2017.

Authors:  Carl Erik Alm; Frede Frihagen; Eva Dybvik; Kjell Matre; Jan Erik Madsen; Jan-Erik Gjertsen
Journal:  J Orthop Surg Res       Date:  2021-01-07       Impact factor: 2.359

9.  Limited Dynamic Hip Screw for Treatment of Intertrochanteric Fractures: A Biomechanical Study.

Authors:  Chunlei Zhang; Bin Zhang; Qirong Dong; Dawei Ge
Journal:  Med Sci Monit       Date:  2018-03-26

10.  Biomechanical Comparison of Three Different Intramedullary Nails for Fixation of Unstable Basicervical Intertrochanteric Fractures of the Proximal Femur: Experimental Studies.

Authors:  Dae-Kyung Kwak; Won-Hyeon Kim; Sung-Jae Lee; Sang-Hyun Rhyu; Chul-Young Jang; Je-Hyun Yoo
Journal:  Biomed Res Int       Date:  2018-12-11       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.