Literature DB >> 15183605

Comparison of metal concentrations in rat tibia tissues with various metallic implants.

Yoshimitsu Okazaki1, Emiko Gotoh, Takeshi Manabe, Kihei Kobayashi.   

Abstract

To compare metal concentrations in tibia tissues with various metallic implants, SUS316L stainless steel, Co-Cr-Mo casting alloy, and Ti-6Al-4V and V-free Ti-15Zr-4Nb-4Ta alloys were implanted into the rat tibia for up to 48 weeks. After the implant was removed from the tibia by decalcification, the tibia tissues near the implant were lyophilized. Then the concentrations of metals in the tibia tissues by microwave acid digestion were determined by inductively coupled plasma-mass spectrometry. Fe concentrations were determined by graphite-furnace atomic absorption spectrometry. The Fe concentration in the tibia tissues with the SUS316L implant was relatively high, and it rapidly increased up to 12 weeks and then decreased thereafter. On the other hand, the Co concentration in the tibia tissues with the Co-Cr-Mo implant was lower, and it increased up to 24 weeks and slightly decreased at 48 weeks. The Ni concentration in the tibia tissues with the SUS316L implant increased up to 6 weeks and then gradually decreased thereafter. The Cr concentration tended to be higher than the Co concentration. This Cr concentration linearly increased up to 12 weeks and then decreased toward 48 weeks in the tibia tissues with the SUS316L or Co-Cr-Mo implant. Minute quantities of Ti, Al and V in the tibia tissues with the Ti-6Al-4V implant were found. The Ti concentration in the tibia tissues with the Ti-15Zr-4Nb-4Ta implant was lower than that in the tibia tissues with the Ti-6Al-4V implant. The Zr, Nb and Ta concentrations were also very low. The Ti-15Zr-4Nb-4Ta alloy with its low metal release in vivo is considered advantageous for long-term implants.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15183605     DOI: 10.1016/j.biomaterials.2004.01.064

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  18 in total

Review 1.  Systemic contact dermatitis and allergy to biomedical devices.

Authors:  Marcella Aquino; Tania Mucci
Journal:  Curr Allergy Asthma Rep       Date:  2013-10       Impact factor: 4.806

Review 2.  Development trends of custom-made orthopedic implants.

Authors:  Yoshimitsu Okazaki
Journal:  J Artif Organs       Date:  2011-08-11       Impact factor: 1.731

3.  Miniscrews for orthodontic anchorage: nanoscale chemical surface analyses.

Authors:  Justin Silverstein; Osmar Barreto; Rodrigo França
Journal:  Eur J Orthod       Date:  2015-03-13       Impact factor: 3.075

4.  Comparisons of immersion and electrochemical properties of highly biocompatible Ti-15Zr-4Nb-4Ta alloy and other implantable metals for orthopedic implants.

Authors:  Yoshimitsu Okazaki; Hiroyuki Nagata
Journal:  Sci Technol Adv Mater       Date:  2012-12-13       Impact factor: 8.090

5.  Promotion of initial cell adhesion on trisuccinimidyl citrate-modified nickel-free high-nitrogen stainless steel.

Authors:  Makoto Sasaki; Motoki Inoue; Yasuyuki Katada; Tetsushi Taguchi
Journal:  J Mater Sci Mater Med       Date:  2013-01-19       Impact factor: 3.896

6.  Surface-protein interactions on different stainless steel grades: effects of protein adsorption, surface changes and metal release.

Authors:  Y Hedberg; X Wang; J Hedberg; M Lundin; E Blomberg; I Odnevall Wallinder
Journal:  J Mater Sci Mater Med       Date:  2013-02-02       Impact factor: 3.896

7.  Mechanical, physical, and chemical characterization of Ti-35Nb-5Zr and Ti-35Nb-10Zr casting alloys.

Authors:  Ana Lúcia Roselino Ribeiro; Rubens Caram Junior; Flávia Farias Cardoso; Romeu Belon Fernandes Filho; Luís Geraldo Vaz
Journal:  J Mater Sci Mater Med       Date:  2009-04-01       Impact factor: 3.896

8.  Assessment of the Quality of Newly Formed Bone around Titanium Alloy Implants by Using X-Ray Photoelectron Spectroscopy.

Authors:  Hiroshi Nakada; Toshiro Sakae; Yasuhiro Tanimoto; Mari Teranishi; Takao Kato; Takehiro Watanabe; Hiroyuki Saeki; Yasuhiko Kawai; Racquel Z Legeros
Journal:  Int J Biomater       Date:  2012-06-18

9.  Assessment of the genetic risks of a metallic alloy used in medical implants.

Authors:  Cristiano C Gomes; Leonardo M Moreira; Vanessa J S V Santos; Alfeu S Ramos; Juliana P Lyon; Cristina P Soares; Fabio V Santos
Journal:  Genet Mol Biol       Date:  2011-03-01       Impact factor: 1.771

10.  Allergy or tolerance: reduced inflammatory cytokine response and concomitant IL-10 production of lymphocytes and monocytes in symptom-free titanium dental implant patients.

Authors:  Peter Thomas; Gerhard Iglhaut; Andreas Wollenberg; Dieter Cadosch; Burkhard Summer
Journal:  Biomed Res Int       Date:  2013-09-11       Impact factor: 3.411

View more