Literature DB >> 15173295

Primary total hip arthroplasty with a porous-coated acetabular component. A concise follow-up of a previous report.

Craig J Della Valle1, Richard A Berger, Susan Shott, Aaron G Rosenberg, Joshua J Jacobs, Laura Quigley, Jorge O Galante.   

Abstract

We previously reported the seven-to-ten-year results of the use of a porous-coated acetabular metal shell in a consecutive series of 204 primary total hip arthroplasties. In the present study, we evaluated the longer-term outcomes of these arthroplasties, at fifteen to eighteen years. One hundred and thirty-six (96%) of the 142 hips available for study retained the original acetabular metal shell. Three of the 142 metal shells failed secondary to aseptic loosening. Ten hips (7%) required a change of the modular acetabular liner because of excessive wear or for the treatment of osteolysis. The fifteen-year rate of survival of the metal shell, with failure defined as revision because of loosening or radiographic evidence of loosening, was 99%. The rate of survival of cementless acetabular reconstructions was excellent at fifteen years, although osteolysis and reoperations were noted to occur much more frequently as the duration of follow-up increased. The majority of the complications were related to wear of the polyethylene liner.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15173295     DOI: 10.2106/00004623-200406000-00014

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  4 in total

1.  [Mega cups and partial pelvic replacement].

Authors:  R von Eisenhart-Rothe; H Gollwitzer; A Toepfer; H Pilge; B M Holzapfel; H Rechl; R Gradinger
Journal:  Orthopade       Date:  2010-10       Impact factor: 1.087

2.  The development of a scanning strategy for the manufacture of porous biomaterials by selective laser melting.

Authors:  R Stamp; P Fox; W O'Neill; E Jones; C Sutcliffe
Journal:  J Mater Sci Mater Med       Date:  2009-06-18       Impact factor: 3.896

3.  Second-generation modular acetabular components provide fixation at 10 to 16 years.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

4.  Direct comparison of polyethylene wear in cemented and uncemented acetabular cups.

Authors:  Håvard Bjerkholt; Oystein Høvik; Olav Reikerås
Journal:  J Orthop Traumatol       Date:  2010-09-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.