Literature DB >> 15165911

Effects of stent length and lesion length on coronary restenosis.

Laura Mauri1, A James O'Malley, Donald E Cutlip, Kalon K L Ho, Jeffrey J Popma, Manish S Chauhan, Donald S Baim, David J Cohen, Richard E Kuntz.   

Abstract

The choice of drug-eluting versus bare metal stents is based on costs and expectations of restenosis and thrombosis risk. Approaches to stent placement vary from covering just the zone of maximal obstruction to stenting well beyond the lesion boundaries (normal-to-normal vessel). The independent effects of stented lesion length, nonstented lesion length, and excess stent length, on coronary restenosis have not been evaluated for bare metal or drug-eluting stents. We analyzed the angiographic follow-up cohort (1,181 patients) from 6 recent bare metal stent trials of de novo lesions in native coronary arteries. Stent length exceeded lesion length in 87% of lesions (mean lesion length 12.4 +/- 6.3 mm, mean stent length 20.0 +/- 7.9 mm, mean difference 7.6 +/- 7.9 mm). At 6- to 9-month follow-up, the mean percent diameter stenosis was 39.1 +/- 20.1%. In an adjusted multivariable model of percent diameter stenosis, each 10 mm of stented lesion length was associated with an absolute increase in percent diameter stenosis of 7.7% (p <0.0001), whereas each 10 mm of excess stent length independently increased percent diameter stenosis by 4.0% (p <0.0001) and increased target lesion revascularization at 9 months (odds ratio 1.12, 95% confidence interval 1.02 to 1.24). Significant nonstented lesion length was uncommon (12.5% of cases). In summary, stent length exceeded lesion length in most stented lesions, and the amount of excess stent length increased the risk of restenosis independent of the stented lesion length. This analysis supports a conservative approach of matching stent length to lesion length to reduce the risk of restenosis with bare metal stents.

Entities:  

Mesh:

Year:  2004        PMID: 15165911     DOI: 10.1016/j.amjcard.2004.02.027

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  17 in total

1.  Cobalt-chromium stents in long lesions of large vessels: clinical and angiographic results.

Authors:  Iñigo Lozano; Carlos Cuellas; Pablo Avanzas; Armando Pérez de Prado; Concepción Suárez; Juan Rondan; Daehyun Lee; Jesus M de la Hera; Felipe Fernández; César Morís
Journal:  Tex Heart Inst J       Date:  2011

2.  Characterizing the spectrum of in-stent restenosis: implications for contemporary treatment.

Authors:  Gordon E Pate; May Lee; Karin Humphries; Eric Cohen; Robert Lowe; Rebecca S Fox; Robert Teskey; Christopher E Buller
Journal:  Can J Cardiol       Date:  2006-12       Impact factor: 5.223

3.  The accuracy of length measurements using different intravascular ultrasound motorized transducer pullback systems.

Authors:  Kaoru Tanaka; Stéphane G Carlier; Gary S Mintz; Koichi Sano; Xuebo Liu; Kenichi Fujii; Jose de Ribamar Costa; Joanna Lui; Jeffrey W Moses; Gregg W Stone; Martin B Leon
Journal:  Int J Cardiovasc Imaging       Date:  2007-03-17       Impact factor: 2.357

4.  Shortening the stent length reduces restenosis with bare metal stents: matched pair comparison of short stenting and conventional stenting.

Authors:  U Dietz; N Holz; C Dauer; H Lambertz
Journal:  Heart       Date:  2005-05-09       Impact factor: 5.994

Review 5.  Robotic-assisted angioplasty: current status and future possibilities.

Authors:  Nathaniel R Smilowitz; Giora Weisz
Journal:  Curr Cardiol Rep       Date:  2012-10       Impact factor: 2.931

6.  Combining short stent implantation and drug-eluting stenting for routine use yields a low restenosis rate.

Authors:  Ulrich Dietz; Cheryl Dauer; Heinz Lambertz
Journal:  Exp Clin Cardiol       Date:  2006

Review 7.  Robotic-Assisted Percutaneous Coronary Intervention.

Authors:  Nathan Lo; Jorge Antonio Gutierrez; Rajesh V Swaminathan
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-02-24

8.  Assessment of three dimensional quantitative coronary analysis by using rotational angiography for measurement of vessel length and diameter.

Authors:  Jin Bae Lee; Sung Gug Chang; So Yeon Kim; Young Soo Lee; Jae Kean Ryu; Ji Yong Choi; Kee Sik Kim; Jae Sik Park
Journal:  Int J Cardiovasc Imaging       Date:  2011-12-18       Impact factor: 2.357

9.  Advances in drug eluting stents - focus on the Endeavor(®) zotarolimus stent.

Authors:  Jonathan Bridges; Donald Cutlip
Journal:  Med Devices (Auckl)       Date:  2008-12-07

10.  Lesion length impacts long term outcomes of drug-eluting stents and bare metal stents differently.

Authors:  Shang-Hung Chang; Chun-Chi Chen; Ming-Jer Hsieh; Chao-Yung Wang; Cheng-Hung Lee; I-Chang Hsieh
Journal:  PLoS One       Date:  2013-01-11       Impact factor: 3.240