Literature DB >> 15162408

Response of heterograft heart valve biomaterials to moderate cyclic loading.

Wei Sun1, Michael Sacks, Gregory Fulchiero, Joshua Lovekamp, Naren Vyavahare, Michael Scott.   

Abstract

We have recently demonstrated that noncalcific tissue damage can lead to significant collagen degradation in clinically explanted bioprosthetic heart valves (BHVs). In the present study we quantified the early response of glutaraldehyde treated bovine pericardium (GLBP) to cyclic tensile loading to begin to elucidate the mechanisms of noncalcific tissue degeneration in BHV biomaterials. GLBP specimens were cycled at 30 Hz to a maximum uniaxial strain of 16% (corresponding to approximately 1-MPa peak stress), with the loading direction parallel to the preferred collagen fiber (PD) direction. After 30 x 10(6) cycles, specimens were subjected to biaxial mechanical testing, then cycled until 65 x 10(6) cycles. The results indicated a permanent change in the unloaded tissue dimensions of +7.1% strain in the PD direction and -7.7% strain in the cross fiber direction (XD) after 65 x 10(6) cycles and an increase of the collagen crimp period from 40.6 to 45.2 microm by 65 x 10(6) cycles (p = 0.05). Fourier transform IR spectroscopy analysis indicated that cyclic fatigue of GLBP leads to both collagen conformational changes and early denaturation. Furthermore, no significant changes in areal strain were found under 1-MPa equibiaxial stress, indicating that cyclic loading changed the collagen fiber orientation but not the overall tissue compliance. These observations suggest that while deterioration of collagen begins immediately, fiber straightening and reorientation dominates the changes in the mechanical behavior up to 65 x 10(6) cycles. The present study underscores the complexity of the response of biologically derived biomaterials to cyclic mechanical loading. Improved understanding of these phenomena can potentially guide the development of novel chemical treatment methods that seek to improve BHV durability by minimizing these degenerative processes. Copyright 2004 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15162408     DOI: 10.1002/jbm.a.30031

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  14 in total

1.  A novel fibre-ensemble level constitutive model for exogenous cross-linked collagenous tissues.

Authors:  Michael S Sacks; Will Zhang; Silvia Wognum
Journal:  Interface Focus       Date:  2016-02-06       Impact factor: 3.906

2.  Fixation of Bovine Pericardium-Based Tissue Biomaterial with Irreversible Chemistry Improves Biochemical and Biomechanical Properties.

Authors:  H Tam; W Zhang; D Infante; N Parchment; M Sacks; N Vyavahare
Journal:  J Cardiovasc Transl Res       Date:  2017-02-17       Impact factor: 4.132

Review 3.  On the Mechanics of Transcatheter Aortic Valve Replacement.

Authors:  Lakshmi P Dasi; Hoda Hatoum; Arash Kheradvar; Ramin Zareian; S Hamed Alavi; Wei Sun; Caitlin Martin; Thuy Pham; Qian Wang; Prem A Midha; Vrishank Raghav; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2016-11-21       Impact factor: 3.934

4.  Modeling the response of exogenously crosslinked tissue to cyclic loading: The effects of permanent set.

Authors:  Will Zhang; Michael S Sacks
Journal:  J Mech Behav Biomed Mater       Date:  2017-07-11

5.  Microcrimped collagen fiber-elastin composites.

Authors:  Jeffrey M Caves; Vivek A Kumar; Wenjun Xu; Nisarga Naik; Mark G Allen; Elliot L Chaikof
Journal:  Adv Mater       Date:  2010-05-11       Impact factor: 30.849

6.  A deep learning approach to estimate chemically-treated collagenous tissue nonlinear anisotropic stress-strain responses from microscopy images.

Authors:  Liang Liang; Minliang Liu; Wei Sun
Journal:  Acta Biomater       Date:  2017-09-20       Impact factor: 8.947

7.  Effect of preconditioning and stress relaxation on local collagen fiber re-alignment: inhomogeneous properties of rat supraspinatus tendon.

Authors:  Kristin S Miller; Lena Edelstein; Brianne K Connizzo; Louis J Soslowsky
Journal:  J Biomech Eng       Date:  2012-03       Impact factor: 2.097

8.  Planar biaxial mechanical behavior of bioartificial tissues possessing prescribed fiber alignment.

Authors:  Choon-Sik Jhun; Michael C Evans; Victor H Barocas; Robert T Tranquillo
Journal:  J Biomech Eng       Date:  2009-08       Impact factor: 2.097

9.  Total ellipse of the heart valve: the impact of eccentric stent distortion on the regional dynamic deformation of pericardial tissue leaflets of a transcatheter aortic valve replacement.

Authors:  Paul S Gunning; Neelakantan Saikrishnan; Ajit P Yoganathan; Laoise M McNamara
Journal:  J R Soc Interface       Date:  2015-12-06       Impact factor: 4.118

10.  The three-dimensional micro- and nanostructure of the aortic medial lamellar unit measured using 3D confocal and electron microscopy imaging.

Authors:  Mary K O'Connell; Sushila Murthy; Samson Phan; Chengpei Xu; Joann Buchanan; Ryan Spilker; Ronald L Dalman; Christopher K Zarins; Winfried Denk; Charles A Taylor
Journal:  Matrix Biol       Date:  2007-11-13       Impact factor: 11.583

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.