Literature DB >> 15161319

HDR brachytherapy with surface applicators: technical considerations and dosimetry.

Albert M Sabbas1, Fridon G Kulidzhanov, Joseph Presser, Mary K Hayes, Dattatreyudu Nori.   

Abstract

HDR surface molds offer an alternative radiotherapy modality to electrons for the treatment of skin lesions. Treatment planning and dosimetry are discussed for two types of surface molds used in our clinic. Standard rectangular applicators are used on a variety of sites where surface curvature is minimal. In these cases an idealized planar geometry is used for treatment planning dose calculations. The calculations yield treatment dose uniformity at the prescription depth in tissue as well as skin dose, as a percentage of the treatment dose, and its dose uniformity. The availability of optimization techniques results in superior dose uniformity at depth but the dose at the skin has to be carefully evaluated. We have studied the dependence of these dosimetric parameters on the size of the surface mold and the type of optimization procedure used in the dosimetry calculations. The second type of surface applicator involves the use of a customized silicone rubber mold attached to a thermoplastic mask of the patient. We have used them to treat lesions of the face where surface curvatures are appreciable and reproducibility of setup is more critical. In these cases a CT data set is used for reconstruction of the catheters, activation of relevant dwell positions and dosimetry, including optimization. Towards establishing effective methods for quality assurance of the optimized HDR surface mold planning calculations, we have compared their dosimetry to both a classical brachytherapy system and to one based on an analytical model of the applicator. The classical system yields an independent verification of the integrated activity used in the planning calculations, whereas the analytical model is used to evaluate depth dose dependence on mold size and optimization.

Entities:  

Mesh:

Year:  2004        PMID: 15161319     DOI: 10.1177/153303460400300304

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  8 in total

Review 1.  Recent developments and best practice in brachytherapy treatment planning.

Authors:  C D Lee
Journal:  Br J Radiol       Date:  2014-06-02       Impact factor: 3.039

Review 2.  Radiotherapy in the Adjuvant and Advanced Setting of CSCC.

Authors:  Paolo Muto; Francesco Pastore
Journal:  Dermatol Pract Concept       Date:  2021-10-01

3.  High-dose-rate brachytherapy using Leipzig applicators for non-melanoma localized skin cancer.

Authors:  Antonio Cassio Assis Pellizzon; Ricardo Fogaroli; Michael Jenwey Chen; Polyana Maia; Guilherme Gondim; Douglas de Castro Guedes; Henderson Ramos; Maria Leticia Gobo Silva
Journal:  J Contemp Brachytherapy       Date:  2020-10-30

4.  Incorporation of Electronic Brachytherapy for Skin Cancer into a Community Dermatology Practice.

Authors:  Stephen Doggett; Mark Willoughby; Cole Willoughby; Erick Mafong; Amy Han
Journal:  J Clin Aesthet Dermatol       Date:  2015-11

5.  High-dose-rate (HDR) plesiotherapy with custom-made moulds for the treatment of non-melanoma skin cancer.

Authors:  Angel Montero; Raúl Hernanz; Ana-Belén Capuz; Eva Fernández; Asunción Hervás; Rafael Colmenares; Alfredo Polo; Sonsoles Sancho; Rafael Molerón; Carmen Vallejo; Alfredo Ramos
Journal:  Clin Transl Oncol       Date:  2009-11       Impact factor: 3.405

6.  Individual applicator for brachytherapy for various sites of superficial malignant lesions.

Authors:  Lukasz Kowalik; Jarosław Lyczek; Marcin Sawicki; Damian Kazalski
Journal:  J Contemp Brachytherapy       Date:  2013-03-29

Review 7.  Novel treatment options for nonmelanoma skin cancer: focus on electronic brachytherapy.

Authors:  Michael E Kasper; Ahmed A Chaudhary
Journal:  Med Devices (Auckl)       Date:  2015-11-26

8.  Two years results of electronic brachytherapy for basal cell carcinoma.

Authors:  Rosa Ballester-Sánchez; Olga Pons-Llanas; Cristian Candela-Juan; Blanca de Unamuno-Bustos; Francisco Javier Celada-Alvarez; Alejandro Tormo-Mico; Jose Perez-Calatayud; Rafael Botella-Estrada
Journal:  J Contemp Brachytherapy       Date:  2017-06-05
  8 in total