Literature DB >> 15158933

Imaging technologies and techniques.

Patrick Rafter1, Patrick Phillips, Mani A Vannan.   

Abstract

Equipment manufacturers provide contrast-specific detection techniques that have excellent sensitivity and excellent agent-to-tissue specificity along with helpful tools that improve workflow efficiency dramatically. Excellent contrast agents have been approved for LV opacification and are available worldwide. Techniques designed for low-MI imaging offer real-time acquisition capabilities and lead to faster examinations. Techniques designed for medium-MI imaging offer better sensitivity than low-MI techniques while maintaining the benefit of rapid image acquisition. Techniques designed for high-MI imaging offer the best sensitivity with longer acquisition times. These techniques are viable means for imaging contrast agents tailored to clinical needs. Progress by contrast agent manufacturers, equipment manufacturers, and physicians will continue to drive improvements in the areas of detection and clinical workflow for improved patient care.

Entities:  

Mesh:

Year:  2004        PMID: 15158933     DOI: 10.1016/j.ccl.2004.02.002

Source DB:  PubMed          Journal:  Cardiol Clin        ISSN: 0733-8651            Impact factor:   2.213


  4 in total

1.  Prognostic value of real time dobutamine stress myocardial contrast echocardiography in patients with chest pain syndrome.

Authors:  Geu-Ru Hong; Jong-Seon Park; Sang-Hee Lee; Dong-Gu Shin; Ung Kim; Jung Hyun Choi; Robin Abdelmalik; Jesús A Vera; Jin-Kyung Kim; Jagat Narula; Mani A Vannan
Journal:  Int J Cardiovasc Imaging       Date:  2011-12-06       Impact factor: 2.357

2.  In vitro measurement of attenuation and nonlinear scattering from echogenic liposomes.

Authors:  Shirshendu Paul; Daniel Russakow; Rahul Nahire; Tapas Nandy; Avinash H Ambre; Kalpana Katti; Sanku Mallik; Kausik Sarkar
Journal:  Ultrasonics       Date:  2012-03-29       Impact factor: 2.890

Review 3.  Assessment and Treatment for Coronary Microvascular Dysfunction by Contrast Enhanced Ultrasound.

Authors:  Junzhen Zhan; Longhe Zhong; Juefei Wu
Journal:  Front Cardiovasc Med       Date:  2022-06-20

4.  Left ventricular free wall impeding rupture in post-myocardial infarction period diagnosed by myocardial contrast echocardiography: case report.

Authors:  Maria Luciana Zacarias Hannouche da Trindade; Jeane Mike Tsutsui; Ana Clara Tude Rodrigues; Márcia Azevedo Caldas; José Antônio Franchini Ramires; Wilson Mathias Junior
Journal:  Cardiovasc Ultrasound       Date:  2006-01-26       Impact factor: 2.062

  4 in total