Photoelastic analysis of the effect of palatal support on various implant-supported overdenture designs.

Kent T Ochiai1, Brian H Williams, Satoru Hojo, Russell Nishimura, Angelo A Caputo.   

Abstract

STATEMENT OF PROBLEM: The effect of palatal support on various types of implant-supported maxillary overdenture designs has not been sufficiently assessed.
PURPOSE: The purpose of this study was to photoelastically evaluate the palatal support of 3 designs of maxillary implant-supported overdentures.
MATERIAL AND METHODS: A photoelastic model of an edentulous maxilla was fabricated with four 3.75 x 13-mm 3i implants. Three maxillary overdenture designs were fabricated: a splinted Hader bar incorporating 2 distal ERA attachments with anterior clips; non-splinted Zaag 4-mm direct abutments and attachments; and nonsplinted Locator 2-mm direct abutments and attachments. All restorative components and attachments were fitted and observed for passivity of fit and alignment. The overdentures were first tested with complete palatal coverage. Unilateral 25-lb loads were applied at the left and right first molars and the incisive papilla area. The photoelastic effects were monitored and recorded photographically. The palatal area was removed from the 3 overdentures and the loading regimens were repeated.
RESULTS: The highest stresses under central loading were seen with the splinted Hader bar and complete palatal coverage, followed by similar levels of stress with either Zaag or Locator attachments. After removal of the palate, the center load demonstrated greater differences between designs. The highest stresses were observed with the Hader bar, followed by the Zaag and then Locator attachments. Lack of palatal coverage demonstrated higher levels of stress around implants and visible supporting tissues. The unilateral load produced the highest stress for the splinted Hader bar, followed by Locator, and then Zaag.
CONCLUSIONS: Removal of the palatal support produced a greater effect and more concentrated stress difference for maxillary overdentures than differences between the attachment designs tested.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15153848     DOI: 10.1016/S0022391304000927

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  8 in total

Review 1.  Immediate loading of overdentures: systematic review.

Authors:  Marcelo Coelho Goiato; Lisiane Cristina Bannwart; Aldiéris Alves Pesqueira; Daniela Micheline dos Santos; Marcela Filié Haddad; Murillo Rezende Santos; Paula Uchoa Castilho
Journal:  Oral Maxillofac Surg       Date:  2013-07-05

2.  Stress-strain distribution at bone-implant interface of two splinted overdenture systems using 3D finite element analysis.

Authors:  Mostafa Omran Hussein
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

3.  Finite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage.

Authors:  Min-Jeong Kim; Sung-Ok Hong
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

4.  Effect of attachment type on load distribution to implant abutments and the residual ridge in mandibular implant-supported overdentures.

Authors:  Nobuhiro Yoda; Yoshiki Matsudate; Masaru Abue; Guang Hong; Keiichi Sasaki
Journal:  J Dent Biomech       Date:  2015-03-16

5.  Effect of cantilever length on stress distribution around implants in mandibular overdentures supported by two and three implants.

Authors:  Behnaz Ebadian; Ramin Mosharraf; Niloufar Khodaeian
Journal:  Eur J Dent       Date:  2016 Jul-Sep

6.  Full Mouth Reconstruction of a Skeletal Class II Division 1 Patient with Adenoid Cystic Carcinoma Using an Interim Immediate Obturator and a Definitive Obturator.

Authors:  Mehran Bahrami; Seyed Mehran Falahchai
Journal:  Case Rep Dent       Date:  2017-04-04

7.  Effect of Implant Location on Palateless Complete Overdenture Retention: an In Vitro Study.

Authors:  Nesma El-Amier; Ehab Elsaih; Mona Gibreel; Hassan El-Motaiam
Journal:  J Oral Maxillofac Res       Date:  2018-09-30

Review 8.  Photoelasticity for Stress Concentration Analysis in Dentistry and Medicine.

Authors:  Miriam Marín-Miranda; Ana María Wintergerst; Yoshamin Abnoba Moreno-Vargas; María Lilia Adriana Juárez-López; Cesar Tavera-Ruiz
Journal:  Materials (Basel)       Date:  2022-09-30       Impact factor: 3.748

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.