Literature DB >> 15152924

Modelling 6 MV photon beams of a stereotactic radiosurgery system for Monte Carlo treatment planning.

Jun Deng1, Thomas Guerrero, C M Ma, Ravinder Nath.   

Abstract

The goal of this work is to build a multiple source model to represent the 6 MV photon beams from a Cyberknife stereotactic radiosurgery system for Monte Carlo treatment planning dose calculations. To achieve this goal, the 6 MV photon beams have been characterized and modelled using the EGS4/BEAM Monte Carlo system. A dual source model has been used to reconstruct the particle phase space at a plane immediately above the secondary collimator. The proposed model consists of two circular planar sources for the primary photons and the scattered photons, respectively. The dose contribution of the contaminant electrons was found to be in the order of 10(-3) of the total maximum dose and therefore has been omitted in the source model. Various comparisons have been made to verify the dual source model against the full phase space simulated using the EGS4/BEAM system. The agreement in percent depth dose (PDD) curves and dose profiles between the phase space and the source model was generally within 2%/1 mm for various collimators (5 to 60 mm in diameter) at 80 to 100 cm source-to-surface distances (SSD). Excellent agreement (within 1%/1 mm) was also found between the dose distributions in heterogeneous lung and bone geometry calculated using the original phase space and those calculated using the source model. These results demonstrated the accuracy of the dual source model for Monte Carlo treatment planning dose calculations for the Cyberknife system.

Entities:  

Mesh:

Year:  2004        PMID: 15152924     DOI: 10.1088/0031-9155/49/9/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  13 in total

1.  Total scatter factors of small beams: a multidetector and Monte Carlo study.

Authors:  Paolo Francescon; Stefania Cora; Carlo Cavedon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

2.  A measurement-based generalized source model for Monte Carlo dose simulations of CT scans.

Authors:  Xin Ming; Yuanming Feng; Ransheng Liu; Chengwen Yang; Li Zhou; Hezheng Zhai; Jun Deng
Journal:  Phys Med Biol       Date:  2017-01-12       Impact factor: 3.609

3.  Breathing-motion-compensated robotic guided stereotactic body radiation therapy : Patterns of failure analysis.

Authors:  Susanne Stera; Panagiotis Balermpas; Mark K H Chan; Stefan Huttenlocher; Stefan Wurster; Christian Keller; Detlef Imhoff; Dirk Rades; Jürgen Dunst; Claus Rödel; Guido Hildebrandt; Oliver Blanck
Journal:  Strahlenther Onkol       Date:  2017-09-05       Impact factor: 3.621

Review 4.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

5.  Treatment Planning Considerations for Robotic Guided Cardiac Radiosurgery for Atrial Fibrillation.

Authors:  Oliver Blanck; Svenja Ipsen; Mark K Chan; Ralf Bauer; Matthias Kerl; Peter Hunold; Volkmar Jacobi; Ralf Bruder; Achim Schweikard; Dirk Rades; Thomas J Vogl; Peter Kleine; Frank Bode; Jürgen Dunst
Journal:  Cureus       Date:  2016-07-20

6.  Equivalent-quality unflattened photon beam modeling, planning, and delivery.

Authors:  Yunfei Huang; Ryan T Flynn; R Alfredo C Siochi; John E Bayouth
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

7.  Sensitivity analysis of an asymmetric Monte Carlo beam model of a Siemens Primus accelerator.

Authors:  Eric C Schreiber; Daren L Sawkey; Bruce A Faddegon
Journal:  J Appl Clin Med Phys       Date:  2012-03-08       Impact factor: 2.102

8.  The influence of field size on stopping-power ratios in- and out-of-field: quantitative data for the BrainLAB m3 micro-multileaf collimator.

Authors:  Michael Taylor; Tanya Kairn; Tomas Kron; Leon Dunn; Peter N Johnston; Rick D Franich
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

9.  A virtual source model for Monte Carlo simulation of helical tomotherapy.

Authors:  Jiankui Yuan; Yi Rong; Quan Chen
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

10.  A single-source photon source model of a linear accelerator for Monte Carlo dose calculation.

Authors:  Obioma Nwankwo; Gerhard Glatting; Frederik Wenz; Jens Fleckenstein
Journal:  PLoS One       Date:  2017-09-08       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.