The Edwards MIRA heart valve prosthesis: a 2-year study.

Rudolf Driever1, Stefan Fuchs, Markus Meissner, Edgar Schmitz, Herbert O Vetter.   

Abstract

BACKGROUND: The Edwards MIRA mechanical heart valve is designed to optimize hemodynamics, reduce thrombogenicity, and avoid mechanical failure with a special hinge mechanism. The purpose of the study was to investigate the clinical performance and postoperative hemodynamic results of the first European patients receiving Edwards MIRA mechanical heart valves.
METHODS: From March 1998 to March 1999 a total of 54 Edwards MIRA valves model numbers 3600 (aortic, n = 44) and 9600 (mitral, n = 10) were implanted in 52 (36 male, 16 female; mean age 61 +/- 10.1 years) consecutive patients undergoing mechanical valve replacement in a prospective study. Follow-up of the patients including physical examination, ECG, blood tests, and Doppler were performed prior to discharge, at 6 months, at 1 year, and at least 2 years postoperatively.
RESULTS: Through October 2001 a total of 172 follow-up examinations were completed (51 patients at discharge, 46 patients at 6 months, 43 patients at 12 months, 32 patients at 2 years or beyond). All patients were in NYHA class I and II at the 6-month and 2+-year follow-up. All the patients stated an improved quality of life. Hospital mortality was 1.9%. There were no complications related to anticoagulation. Mean international normalized ratio at 6 months was 3.2 (range 1.9 to 4.3); lactate dehydrogenase was slightly increased with 264 +/- 103 U/L on average (normal value 80 to 240 U/L). No signs of valvular dysfunction or paravalvular leakage were observed. Mean pressure gradients were related to valve diameter: after mitral valve replacement (size 27, 29, 31 mm: 4.8, 3.2, 2.1 mmHg); after aortic valve replacement (size 19, 21, 23, 25 mm: 12.1, 13.1, 9.3, 8.2 mmHg).
CONCLUSIONS: These preliminary data suggest good hemodynamic function and a low rate of valve-related complications of the Edwards-MIRA mechanical prosthesis.

Entities:  

Mesh:

Year:  2004        PMID: 15151649     DOI: 10.1111/j.0886-0440.2004.04060.x

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  4 in total

1.  Experience with the Edwards MIRA mechanical bileaflet valve in the aortic and mitral positions.

Authors:  Arzum Kale; Ulku Yildiz; Benhur Can; Ozer Kandemir; Hilmi Tokmakoglu; Tevfik Tezcaner; Yaman Zorlutuna
Journal:  Tex Heart Inst J       Date:  2006

2.  Long-term experience with the Sorin Bicarbon and Edwards Mira mechanical valve prostheses in the mitral position.

Authors:  Toshihiro Fukui; Toshihiko Shibata; Yasuyuki Sasaki; Hidekazu Hirai; Manabu Motoki; Yosuke Takahashi; Shigefumi Suehiro
Journal:  Gen Thorac Cardiovasc Surg       Date:  2007-03

3.  Left ventricular mass regression following implantation of MIRA bileaflet valves in patients with severe aortic stenosis.

Authors:  Stefan Toggweiler; Michel Zuber; Katharina Gerber; Reinhard Schläpfer; Paul Erne; Peter Stulz
Journal:  Heart Vessels       Date:  2009-01-23       Impact factor: 2.037

4.  Factors determining patient-prosthesis mismatch after aortic valve replacement--a prospective cohort study.

Authors:  Diana Bonderman; Alexandra Graf; Andreas A Kammerlander; Alfred Kocher; Guenter Laufer; Irene M Lang; Julia Mascherbauer
Journal:  PLoS One       Date:  2013-12-03       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.