Literature DB >> 15147152

Reference change values and power functions.

Natàlia Iglesias Canadell1, Per Hyltoft Petersen, Esther Jensen, Carmen Ricós, Per E Jørgensen.   

Abstract

Repeated samplings and measurements in the monitoring of patients to look for changes are common clinical problems. The "reference change value", calculated as zp x [2 x (CVI2 + CVA2)](1/2), where zp is the z-statistic and CVI and CVA are within-subject and analytical coefficients of variation, respectively, has been used to detect whether a measured difference between measurements is statistically significant. However, a reference change value only detects the probability of false-positives (type I error), and for this reason, a model to calculate the risk of missing significant changes in serial results from individuals (probability of false-negatives) is investigated in this work by means of power functions. Therefore, when an analyte is being monitored in a patient, power functions estimate the probability of detecting a defined real change by measuring the difference. Thus, when a measured difference is the same as the calculated reference change value, then it will be detected in only 50% of situations.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15147152     DOI: 10.1515/CCLM.2004.073

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  5 in total

1.  Making the most of a patient's laboratory data: optimisation of signal-to-noise ratio.

Authors:  Per Hyltoft Petersen
Journal:  Clin Biochem Rev       Date:  2005-11

2.  Biological variation of extracellular matrix biomarkers in patients with stable chronic heart failure.

Authors:  Tobias Täger; Clara Wiebalck; Hanna Fröhlich; Anna Corletto; Hugo A Katus; Lutz Frankenstein
Journal:  Clin Res Cardiol       Date:  2017-08-04       Impact factor: 5.460

3.  Biological variation of the cardiac index in patients with stable chronic heart failure: inert gas rebreathing compared with impedance cardiography.

Authors:  Tobias Täger; Hanna Fröhlich; Jennifer Franke; Karen Slottje; Andrea Horsch; Dietmar Zdunek; Georg Hess; Andreas Dösch; Hugo A Katus; Frank H Wians; Lutz Frankenstein
Journal:  ESC Heart Fail       Date:  2015-06-15

4.  Information from Laboratory Data. Interpretation of Serial Measurements.

Authors:  Natàlia Iglesias Canadell
Journal:  EJIFCC       Date:  2004-06-17

5.  Reference ranges for clinical electrophysiology of vision.

Authors:  C Quentin Davis; Ruth Hamilton
Journal:  Doc Ophthalmol       Date:  2021-04-21       Impact factor: 2.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.