Literature DB >> 15147011

Accelerated simulation of cone beam X-ray scatter projections.

A P Colijn1, F J Beekman.   

Abstract

Monte Carlo (MC) methods can accurately simulate scatter in X-ray imaging. However, when low noise scatter projections have to be simulated these MC simulations tend to be very time consuming. Rapid computation of scatter estimates is essential for several applications. The aim of the work presented in this paper is to speed up the estimation of noise-free scatter projections while maintaining their accuracy. Since X-ray scatter projections are often rather smooth, an approach is chosen whereby a short MC simulation is combined with a data fitting program that is robust to projection truncation and noise. This method allows us to estimate the smooth scatter projection rapidly. The speed-up and accuracy achieved by using the fitting algorithm were validated for the projection simulation of a small animal X-ray CT system. The acceleration that can be obtained over standard MC simulations is typically two orders of magnitude, depending on the accuracy required. The proposed approach may be useful for rapid simulation of patient and animal studies and for correction of the image-degrading effects of scatter in tomography.

Entities:  

Mesh:

Year:  2004        PMID: 15147011     DOI: 10.1109/tmi.2004.825600

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  29 in total

1.  A software-based x-ray scatter correction method for breast tomosynthesis.

Authors:  Steve Si Jia Feng; Ioannis Sechopoulos
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

3.  Assessment of errors caused by X-ray scatter and use of contrast medium when using CT-based attenuation correction in PET.

Authors:  Mohammad Reza Ay; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-04-19       Impact factor: 9.236

4.  Estimating 3-D respiratory motion from orbiting views by tomographic image registration.

Authors:  Rongping Zeng; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2007-02       Impact factor: 10.048

Review 5.  Current status and new horizons in Monte Carlo simulation of X-ray CT scanners.

Authors:  Habib Zaidi; Mohammad Reza Ay
Journal:  Med Biol Eng Comput       Date:  2007-07-05       Impact factor: 2.602

6.  Joint CT/CBCT deformable registration and CBCT enhancement for cancer radiotherapy.

Authors:  Yifei Lou; Tianye Niu; Xun Jia; Patricio A Vela; Lei Zhu; Allen R Tannenbaum
Journal:  Med Image Anal       Date:  2013-02-04       Impact factor: 8.545

7.  Characterization of scatter magnitude and distribution in dedicated breast computed tomography with bowtie filters.

Authors:  Kimberly Kontson; Robert J Jennings
Journal:  J Med Imaging (Bellingham)       Date:  2014-12-18

8.  Estimating scatter from sparsely measured primary signal.

Authors:  Gongting Wu; Christina R Inscoe; Jabari Calliste; Jing Shan; Yueh Z Lee; Otto Zhou; Jianping Lu
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-29

Review 9.  A review of breast tomosynthesis. Part I. The image acquisition process.

Authors:  Ioannis Sechopoulos
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

10.  Multi-material decomposition using statistical image reconstruction for spectral CT.

Authors:  Yong Long; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-04-25       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.