Literature DB >> 15143805

Mueller polarimetric imaging system with liquid crystals.

Blandine Laude-Boulesteix1, Antonello De Martino, Bernard Drévillon, Laurent Schwartz.   

Abstract

We present a new polarimetric imaging system based on liquid-crystal modulators, a spectrally filtered white-light source, and a CCD camera. The whole Mueller matrix image of the sample is measured in approximately 5 s in the transmission mode. The instrument design, together with an original and easy-to-operate calibration procedure, provides high accuracy over a wide spectral range (500-700 nm). This accuracy has been assessed by measurement of a linear polarizer at different orientations and a thick wedged quartz plate as an example of a partially depolarized retarder. Polarimetric images of a stained hepatic biopsy with significant fibrosis have been taken at several wavelengths. The optical properties of Picrosirius Red stained collagen (diattenuation, retardance, and polarizance) have been measured independently from each other between 500 and 700 nm.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15143805     DOI: 10.1364/ao.43.002824

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  8 in total

1.  Complete polarization state generator with one variable retarder and its application for fast and sensitive measuring of two-dimensional birefringence distribution.

Authors:  Michael Shribak
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2011-03-01       Impact factor: 2.129

2.  Polarized light imaging of birefringence and diattenuation at high resolution and high sensitivity.

Authors:  Shalin B Mehta; Michael Shribak; Rudolf Oldenbourg
Journal:  J Opt       Date:  2013-09-01       Impact factor: 2.516

3.  Stokes polarimeter optimization in the presence of shot and Gaussian noise.

Authors:  David Lara; Carl Paterson
Journal:  Opt Express       Date:  2009-11-09       Impact factor: 3.894

4.  A high definition Mueller polarimetric endoscope for tissue characterisation.

Authors:  Ji Qi; Daniel S Elson
Journal:  Sci Rep       Date:  2016-05-12       Impact factor: 4.379

Review 5.  Liquid Crystals: A Novel Approach for Cancer Detection and Treatment.

Authors:  Jayalakshmi Vallamkondu; Edwin Bernard Corgiat; Gollapelli Buchaiah; Ramesh Kandimalla; P Hemachandra Reddy
Journal:  Cancers (Basel)       Date:  2018-11-21       Impact factor: 6.639

6.  Fast spectrally encoded Mueller optical scanning microscopy.

Authors:  Sylvain Rivet; Matthieu Dubreuil; Adrian Bradu; Yann Le Grand
Journal:  Sci Rep       Date:  2019-03-08       Impact factor: 4.379

Review 7.  Optical phantoms for biomedical polarimetry: a review.

Authors:  Joseph Chue-Sang; Mariacarla Gonzalez; Angie Pierre; Megan Laughrey; Ilyas Saytashev; Tatiana Novikova; Jessica C Ramella-Roman
Journal:  J Biomed Opt       Date:  2019-03       Impact factor: 3.170

8.  Dual-Retarder Mueller Polarimetry System for Extraction of Optical Properties of Serum Albumin Protein Media.

Authors:  Quoc-Hung Phan; Chien-Yuan Han; Chi-Hsiang Lien; Thi-Thu-Hien Pham
Journal:  Sensors (Basel)       Date:  2021-05-15       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.