BACKGROUND AND
OBJECTIVE: Arterial catheters are routinely used to sample blood for clotting studies in most cardiothoracic intensive care units. The clotting profile in surgical bleeding after cardiac surgery influences further management. Aspiration and discard of a certain amount of blood from the line, prior to sampling, are assumed to clear heparin contamination. We have investigated this assumption through analysis of the clotting profile by simultaneous arterial line and peripheral venous samples.
METHODS: The morning following cardiac surgery, simultaneous arterial line and peripheral venous blood samples were taken for activated plasma thromboplastin time (APTT) ratio and international normalized ratio (INR) in 49 randomly selected patients. Also, a thromboelastogram analysis (TEG) (n = 7) was made. A survey of 22 UK cardiothoracic intensive care units was carried out to determine the practice for the withdrawal of blood for clotting studies.
RESULTS: The median arterial APTT ratio value was 1.32 +/- 0.52 as compared to the median peripheral APTT ratio value which was 1.1 +/- 0.24 (P < 0.001). INR values were statistically similar by both routes. Heparin contamination was confirmed by TEG which revealed that the R-value for arterial catheter blood samples without heparinase in the cup was higher (406.00 +/- 64.44 s) compared with the value for arterial samples with heparinase in the cup (318.28 +/- 47.26s, P < 0.05). The survey of 22 UK cardiothoracic intensive care units showed that heparinized arterial lines were by far the commonest ports used for blood withdrawal for the measurement of APTT ratio results.
CONCLUSIONS: Samples withdrawn from heparinized arterial lines cannot be relied upon for APTT ratio results.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15141797     DOI: 10.1017/s026502150400506x

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  2 in total

1.  Cardiac catheterization: haemostatic changes in pediatric versus adult patients.

Authors:  Gerd Hoerl; Erwin Tafeit; Bettina Leschnik; Thomas Wagner; Wolfgang Muntean; Guenther Juergens; Martin Koestenberger; Gerhard Cvirn
Journal:  J Thromb Thrombolysis       Date:  2011-10       Impact factor: 2.300

2.  Heparinized solution vs. saline solution in the maintenance of arterial catheters: a double blind randomized clinical trial.

Authors:  Mercedes Del Cotillo; Núria Grané; Maria Llavoré; Salvador Quintana
Journal:  Intensive Care Med       Date:  2007-10-16       Impact factor: 17.440

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.