Literature DB >> 15136054

Multidetector-row computed tomography and magnetic resonance imaging of atherosclerotic lesions in human ex vivo coronary arteries.

Konstantin Nikolaou1, Christoph R Becker, Michael Muders, Gregor Babaryka, Juergen Scheidler, Thomas Flohr, Udo Loehrs, Maximilian F Reiser, Zahi A Fayad.   

Abstract

In the present study, we tested the ability of multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI) to identify and retrospectively characterize atherosclerotic lesions in human ex vivo coronary arteries. Thirteen ex vivo hearts were studied with MDCT and MRI. MDCT-images were obtained with an isotropic voxel size of 0.6mm(3). MR images were obtained with an in-plane resolution of 195 microm and 3mm slice thickness. All images were matched with histopathology sections. For both modalities, the sensitivity for the detection of any atherosclerotic lesion was evaluated, and a retrospective analysis of plaque morphology according to criteria defined by the American Heart Association (AHA) was performed. At histopathology, 28 atherosclerotic lesions were found. 21 and 23 of these lesions were identified by MDCT and MRI, respectively. Both modalities detected a small number of false-positive lesions. After retrospective matching with histopathology, MDCT as well as MRI were able to differentiate typical morpholocigal features for fatty, fibrous or calcified plaque components. Using the information presented in this study, in vivo coronary artery wall imaging using MDCT as well as MRI could be facilitated and supported for future investigations on this subject.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15136054     DOI: 10.1016/j.atherosclerosis.2004.01.041

Source DB:  PubMed          Journal:  Atherosclerosis        ISSN: 0021-9150            Impact factor:   5.162


  26 in total

1.  Characterisation of non-calcified coronary plaque by 16-slice multidetector computed tomography: comparison with histopathological specimens obtained by directional coronary atherectomy.

Authors:  Shigeki Kimura; Taishi Yonetsu; Keiko Suzuki; Mitsuaki Isobe; Yoshito Iesaka; Tsunekazu Kakuta
Journal:  Int J Cardiovasc Imaging       Date:  2011-12-07       Impact factor: 2.357

2.  Plaque imaging with CT coronary angiography: Effect of intra-vascular attenuation on plaque type classification.

Authors:  Erica Maffei; Chiara Martini; Teresa Arcadi; Alberto Clemente; Sara Seitun; Alessandra Zuccarelli; Tito Torri; Nico R Mollet; Alexia Rossi; Onofrio Catalano; Giancarlo Messalli; Filippo Cademartiri
Journal:  World J Radiol       Date:  2012-06-28

3.  Flat-panel versus 64-channel computed tomography for in vivo quantitative characterization of aortic atherosclerotic plaques.

Authors:  Ibrahim Aboshady; Dianna D Cody; Evan M Johnson; Amir Gahremanpour; Deborah Vela; Kamal G Khalil; Herbert L Dupont; James T Willerson; L Maximilian Buja; Gregory W Gladish
Journal:  Int J Cardiol       Date:  2010-12-24       Impact factor: 4.164

4.  Influence of intracoronary attenuation on coronary plaque measurements using multislice computed tomography: observations in an ex vivo model of coronary computed tomography angiography.

Authors:  Filippo Cademartiri; Nico R Mollet; Giuseppe Runza; Nico Bruining; Ronald Hamers; Pamela Somers; Michiel Knaapen; Stefan Verheye; Massimo Midiri; Gabriel P Krestin; Pim J de Feyter
Journal:  Eur Radiol       Date:  2005-03-05       Impact factor: 5.315

Review 5.  Non-invasive multislice CT coronary imaging.

Authors:  Nico R Mollet; Filippo Cademartiri; Pim J de Feyter
Journal:  Heart       Date:  2005-03       Impact factor: 5.994

6.  Advances in cardiac CT imaging: 64-slice scanner.

Authors:  Konstantin Nikolaou; Thomas Flohr; Andreas Knez; Carsten Rist; Bernd Wintersperger; Thorsten Johnson; Maximilian F Reiser; Christoph R Becker
Journal:  Int J Cardiovasc Imaging       Date:  2004-12       Impact factor: 2.357

Review 7.  Imaging techniques for the vulnerable coronary plaque.

Authors:  F Cademartiri; L La Grutta; A Palumbo; E Maffei; A Aldrovandi; R Malagò; F Alberghina; F Pugliese; G Runza; M Belgrano; M Midiri; M A Cova; G P Krestin
Journal:  Radiol Med       Date:  2007-07-24       Impact factor: 3.469

8.  64 Slice multi-detector row cardiac CT.

Authors:  Harpreet K Pannu; Pamela T Johnson; Elliot K Fishman
Journal:  Emerg Radiol       Date:  2008-10-22

9.  Quantification of atherosclerotic coronary plaque components by submillimeter computed tomography.

Authors:  Friedrich Knollmann; Franziska Ducke; Lilian Krist; Tereza Kertesz; Rudolf Meyer; Hans Guski; Roland Felix
Journal:  Int J Cardiovasc Imaging       Date:  2007-09-12       Impact factor: 2.357

10.  How reliable are 40 MHz IVUS and 64-slice MDCT in characterizing coronary plaque composition? An ex vivo study with histopathological comparison.

Authors:  Romain Chopard; Loic Boussel; Pascal Motreff; Gilles Rioufol; Alain Tabib; Philippe Douek; David Meyronet; Didier Revel; Gérard Finet
Journal:  Int J Cardiovasc Imaging       Date:  2010-01-06       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.