Literature DB >> 15132454

Effect of light-emitting diode on bond strength of orthodontic brackets.

Serdar Uşümez1, Tamer Büyükyilmaz, Ali Ihya Karaman.   

Abstract

The aim of this study was to evaluate the effect of light-emitting diode (LED) light curing on shear bond strength (SBS) of orthodontic brackets bonded to teeth. Light exposure of 40 seconds from a conventional halogen-based light-curing unit was used as a control. Eighty human premolars were divided into four groups of 20 each. Brackets were bonded to acid-etched teeth with Transbond XT light-cured adhesive. In the first group, the adhesive was light cured for 40 seconds with a conventional halogen unit (XL3000, 3M). In the other three groups, adhesive was cured with a commercial LED unit (Elipar FreeLight, 3M ESPE) for 10, 20, or 40 seconds. SBS of brackets was measured on a universal testing machine and recorded in megapascals. Adhesive remnant index (ARI) scores were determined after failure of brackets. Data were analyzed using analysis of variance and chi-square tests. No statistically significant differences were found among the SBS values of halogen-based light-cured (13.1 +/- 3.1 MPa) and 20- and 40-second LED-cured (13.9 +/- 4.8 MPa and 12.7 +/- 5.1 MPa) specimens (P > .05). However, 10 seconds of LED curing yielded significantly lower SBS (P < .05). No statistically significant differences were found between the ARI scores among groups. The results of this study are promising for the orthodontic application of LED-curing units, but further compatibility and physical characteristic studies of various orthodontic adhesives and clinical trials should be performed before validation.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15132454     DOI: 10.1043/0003-3219(2004)074<0259:EOLDOB>2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  8 in total

1.  Does a reduction of polymerization time and bonding steps affect the bond strength of brackets?

Authors:  Timea Lamper; Stefanie Steinhäuser-Andresen; Karin C Huth; Nicoleta Ilie; Ekaterini Paschos
Journal:  Clin Oral Investig       Date:  2011-03-30       Impact factor: 3.573

2.  Efficiency of light-emitting diode and halogen units in reducing residual monomers.

Authors:  Felipe de Assis Ribeiro Carvalho; Rhita C Almeida; Marco Antonio Almeida; Lucia H S Cevidanes; Marcia C Amorim M Leite
Journal:  Am J Orthod Dentofacial Orthop       Date:  2010-11       Impact factor: 2.650

3.  Effect of short curing times with a high-intensity light-emitting diode or high-power halogen on shear bond strength of metal brackets before and after thermocycling.

Authors:  Erion Cerekja; Banu Cakirer
Journal:  Angle Orthod       Date:  2011-01-24       Impact factor: 2.079

4.  Effect of light-curing units in shear bond strength of metallic brackets: an in vitro study.

Authors:  Luciana Borges Retamoso; Niége Michelle Lazzari Onofre; Luciane Hann; Ernani Menezes Marchioro
Journal:  J Appl Oral Sci       Date:  2010 Jan-Feb       Impact factor: 2.698

5.  Comparison of Bond Strength of Metal and Ceramic Brackets Bonded with Conventional and High-Power LED Light Curing Units.

Authors:  Javad Chalipa; Yasamin Farajzadeh Jalali; Fatemeh Gorjizadeh; Pedram Baghaeian; Mohammad Hashem Hoseini; Omid Mortezai
Journal:  J Dent (Tehran)       Date:  2016-11

6.  Comparison of Light-Emitting Diode-Curing Unit and Halogen-Based Light-Curing Unit for the Polymerization of Orthodontic Resins: An In vitro Study.

Authors:  Guneet Guram; Junaid Ahmed Shaik
Journal:  J Int Soc Prev Community Dent       Date:  2018-10-08

7.  Shear bond strength of a bracket-bonding system cured with a light-emitting diode or halogen-based light-curing unit at various polymerization times.

Authors:  Sanjay Prasad Gupta; Basanta Kumar Shrestha
Journal:  Clin Cosmet Investig Dent       Date:  2018-04-10

8.  Shear bond strength of metallic brackets photo-activated with light-emitting diode (LED) at different exposure times.

Authors:  Emanuel Braga Rêgo; Fábio Lourenço Romano
Journal:  J Appl Oral Sci       Date:  2007-10       Impact factor: 2.698

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.