Literature DB >> 15127995

Short-term bone response to titanium implants coated with thin radiofrequent magnetron-sputtered hydroxyapatite in rabbits.

Shams Mohammadi1, Marco Esposito, Jan Hall, Lena Emanuelsson, Anatol Krozer, Peter Thomsen.   

Abstract

BACKGROUND: It has been suggested that calcium phosphate (CaP) coatings initiate faster bone growth around implants. A major concern about the viable use of these coatings has been their biologic performance related to the coating characteristics.
PURPOSE: The purpose of this study was to investigate the early bone response to micron- and submicron-thick hydroxyapatite (HA) coatings in cortical and trabecular bone.
MATERIALS AND METHODS: CaP coatings were manufactured by magnetron sputtering. Heat treatment was subsequently used to increase the crystallinity of the coatings. Coatings were characterized by x-ray diffraction, Fourier transform infrared spectroscopy, inductively coupled plasma optical emission spectroscopy (ICP-OES), and stylus profilometry. Four types of CaP-coated implants were used (0.1 microm and 2.0 microm amorphous; 0.1 microm and 2.0 microm crystalline); uncoated machined commercially pure titanium implants served as controls. Four hundred eighty implants were randomly placed in 60 rabbits. Ten animals were followed up for 1 week, 10 for 3 weeks, and 40 for 6 weeks. The bone response was histomorphometrically evaluated.
RESULTS: Coatings with a CaP ratio very close to that of HA were produced. Crystalline coatings significantly improved the early bone-implant contact whereas the amorphous-coated implants behaved similarly to uncoated titanium.
CONCLUSIONS: Crystalline CaP coatings 100 nm thick on titanium implants elicited an improved early bone response compared with that of uncoated titanium implants. No further improvement in the bone response was observed with 2 microm coatings.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 15127995     DOI: 10.1111/j.1708-8208.2003.tb00207.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  11 in total

Review 1.  Titanium oral implants: surface characteristics, interface biology and clinical outcome.

Authors:  Anders Palmquist; Omar M Omar; Marco Esposito; Jukka Lausmaa; Peter Thomsen
Journal:  J R Soc Interface       Date:  2010-06-30       Impact factor: 4.118

Review 2.  A systematic review on the long-term success of calcium phosphate plasma-spray-coated dental implants.

Authors:  B A J A van Oirschot; E M Bronkhorst; J J J P van den Beucken; G J Meijer; J A Jansen; R Junker
Journal:  Odontology       Date:  2016-02-17       Impact factor: 2.634

3.  Cytocompatibility of calcium phosphate coatings deposited by an ArF pulsed laser.

Authors:  Y Hashimoto; M Kawashima; R Hatanaka; M Kusunoki; H Nishikawa; S Hontsu; M Nakamura
Journal:  J Mater Sci Mater Med       Date:  2007-07       Impact factor: 3.896

4.  Cytocompatibility of calcium phosphate coatings deposited by an ArF pulsed laser.

Authors:  Y Hashimoto; M Kawashima; R Hatanaka; M Kusunoki; H Nishikawa; S Hontsu; M Nakamura
Journal:  J Mater Sci Mater Med       Date:  2007-06-28       Impact factor: 3.896

5.  Calcium orthophosphate coatings, films and layers.

Authors:  Sergey V Dorozhkin
Journal:  Prog Biomater       Date:  2012-09-26

6.  Polyether ether ketone implants achieve increased bone fusion when coated with nano-sized hydroxyapatite: a histomorphometric study in rabbit bone.

Authors:  Pär Johansson; Ryo Jimbo; Yoshihito Naito; Per Kjellin; Fredrik Currie; Ann Wennerberg
Journal:  Int J Nanomedicine       Date:  2016-04-06

7.  Inflammatory cell response to ultra-thin amorphous and crystalline hydroxyapatite surfaces.

Authors:  Louise Rydén; Omar Omar; Anna Johansson; Ryo Jimbo; Anders Palmquist; Peter Thomsen
Journal:  J Mater Sci Mater Med       Date:  2016-11-28       Impact factor: 3.896

8.  Vertical osteoconductivity of sputtered hydroxyapatite-coated mini titanium implants after dura mater elevation: Rabbit calvarial model.

Authors:  Xin Wang; Osama Zakaria; Marwa Madi; Shohei Kasugai
Journal:  J Tissue Eng       Date:  2015-06-30       Impact factor: 7.813

9.  Laser-Modified Surface Enhances Osseointegration and Biomechanical Anchorage of Commercially Pure Titanium Implants for Bone-Anchored Hearing Systems.

Authors:  Furqan A Shah; Martin L Johansson; Omar Omar; Hanna Simonsson; Anders Palmquist; Peter Thomsen
Journal:  PLoS One       Date:  2016-06-14       Impact factor: 3.240

10.  A systematic review on the effect of inorganic surface coatings in large animal models and meta-analysis on tricalcium phosphate and hydroxyapatite on periimplant bone formation.

Authors:  Jeanne-Marie Damerau; Susanne Bierbaum; Daniel Wiedemeier; Paula Korn; Ralf Smeets; Gregor Jenny; Johanna Nadalini; Bernd Stadlinger
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2021-07-16       Impact factor: 3.405

View more