Deposition of Foradil P in human lungs: comparison of in vitro and in vivo data.

T Meyer1, P Brand, H Ehlich, R Köbrich, G Meyer, F Riedinger, K Sommerer, T Weuthen, G Scheuch.   

Abstract

In order to characterize the efficacy of dry powder inhalers, in vitro measurements are much easier to perform than human deposition studies, especially in early stages of drug development. In this study, lung deposition and delivered dose of radiolabeled Foradil P inhaled with the Aerolizer were measured in 10 healthy subjects. These data were then compared with data derived from an in vitro assessment of the device output and particle size distribution combined with mathematical modeling of lung deposition (modified ICRP-model). Delivered dose and lung deposition increased slightly but statistically significant with the inhalation peak flow in both the in vivo data and the in vitro data. The delivered dose ranged from 60% to 80% and lung deposition, relative to the fill weight, from 13% to 28%. Differences between the in vitro and in vivo data were slight and statistically not significant. This study indicates that in vitro assessment of device performance, in combination with lung deposition delivery data, are in good agreement with deposition data measured in healthy subjects. Since there was only a slight flow rate dependency of lung deposition without clinical relevance, it may additionally be concluded that the Aerolizer is a robust, easy to handle inhalation device with stable and reproducible drug delivery characteristics.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15120012     DOI: 10.1089/089426804322994451

Source DB:  PubMed          Journal:  J Aerosol Med        ISSN: 0894-2684


  3 in total

1.  Influence of air flow on the performance of a dry powder inhaler using computational and experimental analyses.

Authors:  Matthew S Coates; Hak-Kim Chan; David F Fletcher; Judy A Raper
Journal:  Pharm Res       Date:  2005-08-24       Impact factor: 4.200

2.  De-agglomeration Effect of the US Pharmacopeia and Alberta Throats on Carrier-Based Powders in Commercial Inhalation Products.

Authors:  Sharon Shui Yee Leung; Patricia Tang; Qi Tony Zhou; Zhenbo Tong; Cassandra Leung; Janwit Decharaksa; Runyu Yang; Hak-Kim Chan
Journal:  AAPS J       Date:  2015-07-23       Impact factor: 4.009

Review 3.  Lung Deposition and Inspiratory Flow Rate in Patients with Chronic Obstructive Pulmonary Disease Using Different Inhalation Devices: A Systematic Literature Review and Expert Opinion.

Authors:  Adolfo Baloira; Araceli Abad; Antonia Fuster; Juan Luis García Rivero; Patricia García-Sidro; Eduardo Márquez-Martín; Marta Palop; Néstor Soler; J L Velasco; Fernando González-Torralba
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2021-04-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.