Literature DB >> 15117186

Detection of femtomolar concentrations of HF Using an SiO(2) microcantilever.

Yanjun Tang1, Ji Fang, Xiaohe Xu, Hai-Feng Ji, Gilbert M Brown, Thomas Thundat.   

Abstract

Femtomolar concentrations of hydrogen fluoride, a decomposition component of nerve agents, were detected using a SiO(2) microcantilever. The microcantilever underwent bending due to the reaction of HF with SiO(2). The microcantilever deflection increased as the concentration of HF increased. Other acids, such as HCl, had no effect on the deflection of the cantilever. The mechanism of reaction-induced bending and the correlation of microcantilever deflection with the HF concentration are discussed. The deflection in response to HF of a commercially available silicon cantilever was also studied, and its response was compared with that of the SiO(2) cantilever. Much less bending amplitude and sensitivity were observed for the silicon cantilever.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15117186     DOI: 10.1021/ac035140g

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Microcantilevers modified by specific peptide for selective detection of trimethylamine.

Authors:  Xin Huang; Mingfu Li; Xiaohe Xu; Hongjun Chen; Hai-Feng Ji; Shuifang Zhu
Journal:  Biosens Bioelectron       Date:  2011-09-16       Impact factor: 10.618

Review 2.  Measurement of Mechanical Properties of Cantilever Shaped Materials.

Authors:  Eric Finot; Ali Passian; Thomas Thundat
Journal:  Sensors (Basel)       Date:  2008-05-26       Impact factor: 3.576

3.  Detection of hydrofluoric acid by a SiO2 sol-gel coating fiber-optic probe based on reflection-based localized surface plasmon resonance.

Authors:  I-Cherng Chen; Shiu-Shiung Lin; Tsao-Jen Lin; Je-Kang Du
Journal:  Sensors (Basel)       Date:  2011-02-01       Impact factor: 3.576

4.  A self-sensing piezoelectric microcantilever biosensor for detection of ultrasmall adsorbed masses: theory and experiments.

Authors:  Samira Faegh; Nader Jalili; Srinivas Sridhar
Journal:  Sensors (Basel)       Date:  2013-05-10       Impact factor: 3.576

5.  Dual-channel microcantilever heaters for volatile organic compound detection and mixture analysis.

Authors:  Ifat Jahangir; Goutam Koley
Journal:  Sci Rep       Date:  2016-07-06       Impact factor: 4.379

6.  Detection of feline coronavirus using microcantilever sensors.

Authors:  Sreepriya Velanki; Hai-Feng Ji
Journal:  Meas Sci Technol       Date:  2006-10-05       Impact factor: 2.046

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.