Literature DB >> 15114637

Magnetic field from spot welding equipment--is the basic restriction exceeded?

Mohammad Nadeem1, Yngve Hamnerius, Kjell Hansson Mild, Mikael Persson.   

Abstract

A point measurement of the magnetic field (MF) near a typical spot welding machine showed that the magnetic flux density was above the ICNIRP reference level. To investigate if the basic restrictions were exceeded, the induced body currents in a full 3D human model were calculated. It was found that at an operator position of 34 cm away from the machine the maximum induced current density was below the ICNIRP basic restriction. But if the operator was closer to the machine, the basic restriction was exceeded. An important finding of the present article is that the basic restriction can be exceeded although the MF spatially averaged over the whole body is well below the reference level. Copyright 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 15114637     DOI: 10.1002/bem.10197

Source DB:  PubMed          Journal:  Bioelectromagnetics        ISSN: 0197-8462            Impact factor:   2.010


  1 in total

Review 1.  The revised electromagnetic fields directive and worker exposure in environments with high magnetic flux densities.

Authors:  Rianne Stam
Journal:  Ann Occup Hyg       Date:  2014-02-20