Literature DB >> 15113686

Microbead-based electrochemical immunoassay with interdigitated array electrodes.

Jennifer H Thomas1, Sang Kyung Kim, Peter J Hesketh, H Brian Halsall, William R Heineman.   

Abstract

The objective of this study was to develop a sensitive and miniaturized immunoassay by coupling a microbead-based immunoassay with an interdigitated array (IDA) electrode. An IDA electrode amplifies the signal by recycling an electrochemically redox-reversible molecule. The microfabricated platinum electrodes had 25 pairs of electrodes with 1.6-microm gaps and 2.4-microm widths. An enzyme-labeled sandwich immunoassay on paramagnetic microbeads with mouse IgG as the analyte and beta-galactosidase as the enzyme label was used as the model system. beta-Galactosidase converted p-aminophenyl beta-D-galactopyranoside to p-aminophenol (PAP). This enzyme reaction was measured continuously by positioning the microbeads near the electrode surface with a magnet. Electrochemical recycling occurred with PAP oxidation to p-quinone imine (PQI) at +290 mV followed by PQI reduction to PAP at -300 mV vs Ag/AgCl. Dual-electrode detection amplified the signal fourfold compared to single-electrode detection, and the recycling efficiency reached 87%. A calibration curve of PAP concentration vs anodic current was linear between 10(-4) and 10(-6)M. A signal from 1000 beads in a 20-microL drop was detectable and the immunoassay was complete within 10 min with a detection limit of 3.5x10(-15)mol mouse IgG.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15113686     DOI: 10.1016/j.ab.2004.02.020

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  5 in total

1.  High sensitivity carbon nanotube based electrochemiluminescence sensor array.

Authors:  Anita Venkatanarayanan; Karl Crowley; Elena Lestini; Tia E Keyes; James F Rusling; Robert J Forster
Journal:  Biosens Bioelectron       Date:  2011-10-20       Impact factor: 10.618

2.  Dithiobis(succinimidyl propionate) modified gold microarray electrode based electrochemical immunosensor for ultrasensitive detection of cortisol.

Authors:  Sunil K Arya; Ganna Chornokur; Manju Venugopal; Shekhar Bhansali
Journal:  Biosens Bioelectron       Date:  2010-03-18       Impact factor: 10.618

3.  Magnetic particles in ultrasensitive biomarker protein measurements for cancer detection and monitoring.

Authors:  Vigneshwaran Mani; Bhaskara V Chikkaveeraiah; James F Rusling
Journal:  Expert Opin Med Diagn       Date:  2011-09-01

Review 4.  Electrochemical immunosensors for detection of cancer protein biomarkers.

Authors:  Bhaskara V Chikkaveeraiah; Ashwinkumar A Bhirde; Nicole Y Morgan; Henry S Eden; Xiaoyuan Chen
Journal:  ACS Nano       Date:  2012-08-06       Impact factor: 15.881

5.  Development of an Interdigitated Electrode-Based Disposable Enzyme Sensor Strip for Glycated Albumin Measurement.

Authors:  Mika Hatada; Noya Loew; Junko Okuda-Shimazaki; Mukund Khanwalker; Wakako Tsugawa; Ashok Mulchandani; Koji Sode
Journal:  Molecules       Date:  2021-01-31       Impact factor: 4.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.