Literature DB >> 15109849

Long-term in vivo biostability of poly(dimethylsiloxane)/poly(hexamethylene oxide) mixed macrodiol-based polyurethane elastomers.

Anne Simmons1, Jari Hyvarinen, Ross A Odell, Darren J Martin, Pathiraja A Gunatillake, Kathryn R Noble, Laura A Poole-Warren.   

Abstract

The long-term biostability of a novel thermoplastic polyurethane elastomer (Elast-Eon 2 80A) synthesized using poly(hexamethylene oxide) (PHMO) and poly(dimethylsiloxane) (PDMS) macrodiols has been studied using an in vivo ovine model. The material's biostability was compared with that of three commercially available control materials, Pellethane 2363-80A, Pellethane 2363-55D and Bionate 55D, after subcutaneous implantation of strained compression moulded flat sheet dumbbells in sheep for periods ranging from 3 to 24 months. Scanning electron microscopy, attenuated total reflectance-Fourier transform infrared spectroscopy, and X-ray photoelectron spectroscopy were used to assess changes in the surface chemical structure and morphology of the materials. Gel permeation chromatography, differential scanning calorimetry and tensile testing were used to examine changes in bulk characteristics of the materials. The results showed that the biostability of the soft flexible PDMS-based test polyurethane was significantly better than the control material of similar softness, Pellethane 80A, and as good as or better than both of the harder commercially available negative control polyurethanes, Pellethane 55D and Bionate 55D. Changes observed in the surface of the Pellethane materials were consistent with oxidation of the aliphatic polyether soft segment and hydrolysis of the urethane bonds joining hard to soft segment with degradation in Pellethane 80A significantly more severe than that observed in Pellethane 55D. Very minor changes were seen on the surfaces of the Elast-Eon 2 80A and Bionate 55D materials. There was a general trend of molecular weight decreasing with time across all polymers and the molecular weights of all materials decreased at a similar relative rate. The polydispersity ratio, Mw/Mn, increased with time for all materials. Tensile tests indicated that UTS increased in Elast-Eon 2 80A and Bionate 55D following implantation under strained conditions. However, ultimate strain decreased and elastic modulus increased in the explanted specimens of all three materials when compared with their unimplanted unstrained counterparts. The results indicate that a soft, flexible PDMS-based polyurethane synthesized using 20% PHMO and 80% PDMS macrodiols has excellent long-term biostability compared with commercially available polyurethanes.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15109849     DOI: 10.1016/j.biomaterials.2004.01.004

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  13 in total

Review 1.  Tissue-engineered heart valve: future of cardiac surgery.

Authors:  Radoslaw A Rippel; Hossein Ghanbari; Alexander M Seifalian
Journal:  World J Surg       Date:  2012-07       Impact factor: 3.352

2.  A case of Durata ICD lead coil externalization: Inside-out lead abrasion?

Authors:  Ian E Mann; Oliver R Segal
Journal:  HeartRhythm Case Rep       Date:  2016-04-25

3.  Blended Polyurethane and Tropoelastin as a Novel Class of Biologically Interactive Elastomer.

Authors:  Steven G Wise; Hongjuan Liu; Giselle C Yeo; Praveesuda L Michael; Alex H P Chan; Alan K Y Ngo; Marcela M M Bilek; Shisan Bao; Anthony S Weiss
Journal:  Tissue Eng Part A       Date:  2016-03       Impact factor: 3.845

4.  Proteins, platelets, and blood coagulation at biomaterial interfaces.

Authors:  Li-Chong Xu; James W Bauer; Christopher A Siedlecki
Journal:  Colloids Surf B Biointerfaces       Date:  2014-09-28       Impact factor: 5.268

5.  In vivo biostability of polymeric spine implants: retrieval analyses from a United States investigational device exemption study.

Authors:  Ming Shen; Kai Zhang; Petra Koettig; William C Welch; John M Dawson
Journal:  Eur Spine J       Date:  2011-05-03       Impact factor: 3.134

6.  Synthesis of macroporous poly(dimethylsiloxane) scaffolds for tissue engineering applications.

Authors:  Eileen Pedraza; Ann-Christina Brady; Christopher A Fraker; Cherie L Stabler
Journal:  J Biomater Sci Polym Ed       Date:  2012-10-31       Impact factor: 3.517

7.  In vivo cytokine-associated responses to biomaterials.

Authors:  Robert J Schutte; Lola Xie; Bruce Klitzman; William M Reichert
Journal:  Biomaterials       Date:  2008-10-11       Impact factor: 12.479

8.  Manufacturing of biodegradable polyurethane scaffolds based on polycaprolactone using a phase separation method: physical properties and in vitro assay.

Authors:  Azadeh Asefnejad; Mohammad Taghi Khorasani; Aliasghar Behnamghader; Babak Farsadzadeh; Shahin Bonakdar
Journal:  Int J Nanomedicine       Date:  2011-10-18

9.  Investigating the Suitability of Carbon Nanotube Reinforced Polymer in Transcatheter Valve Applications.

Authors:  Monica M Rozeik; David J Wheatley; Terence Gourlay
Journal:  Cardiovasc Eng Technol       Date:  2017-06-16       Impact factor: 2.495

10.  Failure of a novel silicone-polyurethane copolymer (Optim™) to prevent implantable cardioverter-defibrillator lead insulation abrasions.

Authors:  Robert G Hauser; Raed H Abdelhadi; Deepa M McGriff; Linda Kallinen Retel
Journal:  Europace       Date:  2012-08-21       Impact factor: 5.214

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.