Literature DB >> 15106141

Patches of different types for carotid patch angioplasty.

R Bond1, K Rerkasem, R Naylor, P M Rothwell.   

Abstract

BACKGROUND: Some surgeons who use carotid patching favour using a patch made from an autologous vein, whilst others prefer to use synthetic materials.
OBJECTIVES: The objective of this review was to assess the safety and efficacy of different materials for carotid patch angioplasty. SEARCH STRATEGY: We searched the Cochrane Stroke Group trials register (last searched November 2002). In addition, we searched the Cochrane Controlled Trials Register (The Cochrane Library, Issue 4, 2001), MEDLINE (1966 to December 2001), EMBASE (1980 to December 2001) and Index to Scientific and Technical Proceedings (1980 to 2001). We also handsearched eight journals and five conference proceedings. Reference lists were checked and we contacted experts in the field to identify further published and unpublished studies. SELECTION CRITERIA: Randomised and quasi-randomised trials comparing one type of carotid patch with another for carotid endarterectomy. DATA COLLECTION AND ANALYSIS: Two reviewers independently assessed eligibility, trial quality, and extracted the data MAIN
RESULTS: The previous version of this review included three trials involving 326 operations. Since then a further five trials have been reported, increasing the number of operations to 1480. Prior to 1995, all studies had compared vein closure with PTFE closure, but three of the later studies compared vein to Dacron grafts instead and one compared Dacron with PTFE. Allocation was not adequately concealed in two trials, and one only followed up patients to the time of hospital discharge. Intention to treat analysis was possible for six trials. In all but two trials a patient could be randomised twice and have each carotid artery randomised to different treatment groups. There were too few operative events to determine whether there was any difference between the vein and Dacron patches for perioperative stroke, death and arterial complications. The one study that compared Dacron and PTFE patches found a significant risk of combined stroke and transient ischaemic attack (p = 0.03) and restenosis at 30 days (p = 0.01), a borderline significant risk of perioperative stroke (p = 0.06), and a non significant increased risk of perioperative carotid thrombosis (p = 0.1) with dacron compared with PTFE. Five trials followed up patients for longer than 30 days. During follow-up for more than one year, no difference was shown between the two types of patch for the risk of stroke, death, or arterial restenosis. However, the number of events was small. Based on 15 events in 776 patients in four trials, there were significantly fewer pseudoaneurysms associated with synthetic patches than vein (odds ratio [OR] 0.09, 95% confidence interval [CI] 0.02 to 0.49) but the numbers involved were small and the clinical significance of this finding is uncertain. REVIEWERS'
CONCLUSIONS: It is likely that the differences between different types of patch material are very small. Consequently, many more data than are currently available will be required to establish whether any differences do exist. Some evidence exists that PTFE patches may be superior to Colagen impregnated Dacron grafts in terms of perioperative stroke rates and restenosis. However the evidence is based upon data from a single, small trial and more studies that compare different types of synthetic graft are required to make firm conclusions. Psuedo aneurysm formation may be more common after use of a vein patch compared with a synthetic patch.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15106141     DOI: 10.1002/14651858.CD000071.pub2

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  10 in total

1.  Comparative analysis of the biaxial mechanical behavior of carotid wall tissue and biological and synthetic materials used for carotid patch angioplasty.

Authors:  Alexey V Kamenskiy; Iraklis I Pipinos; Jason N MacTaggart; Syed A Jaffar Kazmi; Yuris A Dzenis
Journal:  J Biomech Eng       Date:  2011-11       Impact factor: 2.097

Review 2.  Patches for carotid artery endarterectomy: current materials and prospects.

Authors:  Akihito Muto; Toshiya Nishibe; Herbert Dardik; Alan Dardik
Journal:  J Vasc Surg       Date:  2009-07       Impact factor: 4.268

Review 3.  Management of extracranial carotid artery disease.

Authors:  Yinn Cher Ooi; Nestor R Gonzalez
Journal:  Cardiol Clin       Date:  2015-02       Impact factor: 2.213

Review 4.  Patches of different types for carotid patch angioplasty.

Authors:  Kittipan Rerkasem; Peter M Rothwell
Journal:  Cochrane Database Syst Rev       Date:  2010-03-17

Review 5.  Patch angioplasty versus primary closure for carotid endarterectomy.

Authors:  Saritphat Orrapin; Thoetphum Benyakorn; Boonying Siribumrungwong; Kittipan Rerkasem
Journal:  Cochrane Database Syst Rev       Date:  2022-08-03

Review 6.  Comparative Review of the Treatment Methodologies of Carotid Stenosis.

Authors:  Coney Bae; Mauricio Szuchmacher; John B Chang
Journal:  Int J Angiol       Date:  2015-05-18

7.  Patches of different types for carotid patch angioplasty.

Authors:  Saritphat Orrapin; Thoetphum Benyakorn; Dominic Pj Howard; Boonying Siribumrungwong; Kittipan Rerkasem
Journal:  Cochrane Database Syst Rev       Date:  2021-02-18

Review 8.  Systematic review of randomized controlled trials of different types of patch materials during carotid endarterectomy.

Authors:  Shiyan Ren; Xianlun Li; Jianyan Wen; Wenjian Zhang; Peng Liu
Journal:  PLoS One       Date:  2013-01-31       Impact factor: 3.240

Review 9.  Patch angioplasty versus primary closure for carotid endarterectomy.

Authors:  Kittipan Rerkasem; Peter M Rothwell
Journal:  Cochrane Database Syst Rev       Date:  2009-10-07

10.  Right carotid-cutaneous fistula and right carotid pseudoaneurysm formation secondary to a chronically infected polyethylene terephthalate patch.

Authors:  W T Hillman Terzian; Samuel Schadt; Sharvil U Sheth
Journal:  Int J Crit Illn Inj Sci       Date:  2018 Jan-Mar
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.