Literature DB >> 15105166

Remotely controlled mandibular positioner predicts efficacy of oral appliances in sleep apnea.

Willis H Tsai1, Juan-Carlos Vazquez, Tsutomu Oshima, Leslie Dort, Brian Roycroft, Alan A Lowe, Eric Hajduk, John E Remmers.   

Abstract

Anterior mandibular positioners (AMPs) have become increasingly popular as alternatives to continuous positive airway pressure for the treatment of obstructive sleep apnea. However, widespread acceptance of AMP is limited by an efficacy rate of 50-80% and an inability to predict which patients will respond to therapy. We evaluated 23 patients with obstructive sleep apnea (respiratory disturbance index [RDI] >/= 15 h(-1)) with a remotely controlled mandibular positioner (RCMP), a temporary oral appliance that can advance or retract the mandible in a process analogous to changing the mask pressure during a continuous positive airway pressure titration study. We hypothesized that the elimination of respiratory events and significant nocturnal oxygen desaturation during an RCMP overnight study would predict AMP efficacy, as defined by an absolute reduction in RDI to less than 15 h(-1), a relative reduction in RDI of more than 30% from baseline, and a subjective improvement in symptoms. AMP compliance was 82%, and therapeutic efficacy was 53%. Among compliant patients, the positive and negative predictive value of an RCMP study in predicting AMP treatment success was 90% and 89%, respectively. An overnight RCMP study is highly predictive of AMP response.

Entities:  

Mesh:

Year:  2004        PMID: 15105166     DOI: 10.1164/rccm.200310-1446OC

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


  24 in total

Review 1.  Sleep medicine care under one roof: a proposed model for integrating dentistry and medicine.

Authors:  Sunil Sharma; Greg Essick; David Schwartz; Amy J Aronsky
Journal:  J Clin Sleep Med       Date:  2013-08-15       Impact factor: 4.062

2.  Another advance in oral appliance therapy?

Authors:  Patrick J Strollo
Journal:  Sleep       Date:  2013-10-01       Impact factor: 5.849

3.  The efficacy of oral appliances in the treatment of severe obstructive sleep apnea.

Authors:  Bing Lam; Kim Sam; Jamie C M Lam; Agnes Y K Lai; Chi-Leung Lam; Mary S M Ip
Journal:  Sleep Breath       Date:  2011-02-20       Impact factor: 2.816

4.  A Feedback-Controlled Mandibular Positioner Identifies Individuals With Sleep Apnea Who Will Respond to Oral Appliance Therapy.

Authors:  John E Remmers; Zbigniew Topor; Joshua Grosse; Nikola Vranjes; Erin V Mosca; Rollin Brant; Sabina Bruehlmann; Shouresh Charkhandeh; Seyed Abdolali Zareian Jahromi
Journal:  J Clin Sleep Med       Date:  2017-07-15       Impact factor: 4.062

5.  Oral appliances for treatment of snoring and obstructive sleep apnea: a review of clinical effectiveness.

Authors: 
Journal:  CADTH Technol Overv       Date:  2010-03-01

6.  Performance of Remotely Controlled Mandibular Protrusion Sleep Studies for Prediction of Oral Appliance Treatment Response.

Authors:  Kate Sutherland; Joachim Ngiam; Peter A Cistulli
Journal:  J Clin Sleep Med       Date:  2017-03-15       Impact factor: 4.062

7.  Nasal pressure recordings to detect obstructive sleep apnea.

Authors:  Fernanda Ribeiro de Almeida; Najib T Ayas; Ryo Otsuka; Hiroshi Ueda; Peter Hamilton; Frank C Ryan; Alan A Lowe
Journal:  Sleep Breath       Date:  2006-06       Impact factor: 2.816

8.  A combination appliance for obstructive sleep apnea: the effectiveness of mandibular advancement and tongue retention.

Authors:  Leslie Dort; John Remmers
Journal:  J Clin Sleep Med       Date:  2012-06-15       Impact factor: 4.062

Review 9.  The Use of Remotely Controlled Mandibular Positioner as a Predictive Screening Tool for Mandibular Advancement Device Therapy in Patients with Obstructive Sleep Apnea through Single-Night Progressive Titration of the Mandible: A Systematic Review.

Authors:  Chloé Kastoer; Marijke Dieltjens; Eline Oorts; Evert Hamans; Marc J Braem; Paul H Van de Heyning; Olivier M Vanderveken
Journal:  J Clin Sleep Med       Date:  2016-10-15       Impact factor: 4.062

10.  Effect of a titration polysomnogram on treatment success with a mandibular repositioning appliance.

Authors:  Fernanda R Almeida; Jonathan A Parker; James S Hodges; Alan A Lowe; Kathleen A Ferguson
Journal:  J Clin Sleep Med       Date:  2009-06-15       Impact factor: 4.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.