Literature DB >> 15103292

Patient radiation doses and references levels in interventional radiology.

Marco Brambilla1, Giuseppe Marano, Marco Dominietto, Antonio Raffaele Cotroneo, Alessandro Carriero.   

Abstract

PURPOSE: To set Diagnostic Reference Levels (DRLs) in interventional radiology by means of dose area product (DAP) measurements and the grouping of homogeneous procedures, and to quantify the associated errors in the DRL estimates. To evaluate the Mean Effective Doses per single procedure.
MATERIALS AND METHODS: Interventional radiology procedures were divided into four main groups: neuroradiological, vascular, extravascular and paediatric. Neuroradiological and vascular procedures were further divided into diagnostic and interventional procedures. Starting from DAP and total fluoroscopy time measurements in 1,256 patients, the DRLs were determined for 17 procedures, together with an estimate of their uncertainty. The correlation between fluoroscopy time and DAP was assessed. Mean effective dose estimates were obtained from measured DAP values and from the analysis of the dosimetric data reported in the literature for similar procedures.
RESULTS: The main features of DAP distributions are long high-dose tails, indicating asymmetric distributions, together with a large interquartile range. Rounded third-quartile values of DAP distributions showed a large range in the procedures taken into consideration. Values of 147, 198, 338 Gy cm(2)were obtained for supra-aortic angiography, cerebral angiography and embolization. Values of 86-101 and 459-438 Gy cm(2)were obtained for diagnostic and interventional vascular procedures on the lower limbs and on the abdomen, respectively. Values of 25-33 Gy cm(2)were obtained for retrograde cystourethrographies and ERCP, and values of 62-158 Gy cm(2)were obtained for nephrostomy and percutaneous transhepatic cholangiography. The correlation between total fluoroscopy time and the DAP values was poor. Mean effective dose estimates showed lower values for extravascular procedures (4.8-28.2 mSv), intermediate values for neuroradiological procedures (12.6-32.9 mSv) and higher values for vascular procedures involving the abdomen (36.5-86.8 mSv). DISCUSSION: DAP values were generally higher in vascular than in extravascular procedures. In generally, interventional vascular procedures show higher DAP values than the corresponding diagnostic procedures, with the exception of the abdominal region where the values were similar. Extravascular procedures with percutaneous access show significantly higher DAP values than those with endoscopic access. Total fluoroscopy time is a poor predictor of patient doses in interventional radiology.
CONCLUSIONS: The systematic recording of DAP values, together with adequate grouping of similar procedures makes it possible to establish stable DRLs on a local basis and to carry out dosimetric evaluations, although on a statistical rather than individual basis. Patient radiation doses during interventional radiological procedures may be high, particularly when the abdominal region is involved.

Entities:  

Mesh:

Year:  2004        PMID: 15103292

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  14 in total

1.  How to set up and apply reference levels in fluoroscopy at a national level.

Authors:  A Aroua; H Rickli; J-C Stauffer; P Schnyder; P R Trueb; J-F Valley; P Vock; F R Verdun
Journal:  Eur Radiol       Date:  2006-10-27       Impact factor: 5.315

2.  Patient radiation doses and reference levels in pediatric interventional radiology.

Authors:  Bouchra Habib Geryes; Adeline Bak; Julie Lachaux; Augustin Ozanne; Nathalie Boddaert; Francis Brunelle; Olivier Naggara; Guillaume Saliou
Journal:  Eur Radiol       Date:  2017-02-16       Impact factor: 5.315

3.  Reference levels for patient radiation doses in interventional radiology: proposed initial values for U.S. practice.

Authors:  Donald L Miller; Deukwoo Kwon; Grant H Bonavia
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

4.  Reference levels and patient doses in interventional cardiology procedures in Greece.

Authors:  George Simantirakis; Christina Koukorava; Maria Kalathaki; Christos Pafilis; Ioannis Kaisas; Sotirios Economides; Costas J Hourdakis; Vassiliki Kamenopoulou; Evaggelos Georgiou
Journal:  Eur Radiol       Date:  2013-04-06       Impact factor: 5.315

5.  Image Quality of Low-Dose Cerebral Angiography and Effectiveness of Clinical Implementation on Diagnostic and Neurointerventional Procedures for Intracranial Aneurysms.

Authors:  J Choi; B Kim; Y Choi; N Y Shin; J Jang; H S Choi; S L Jung; K J Ahn
Journal:  AJNR Am J Neuroradiol       Date:  2019-04-04       Impact factor: 3.825

6.  Measures of patient radiation exposure during endoscopic retrograde cholangiography: beyond fluoroscopy time.

Authors:  Toufic Kachaamy; Edwyn Harrison; Rahul Pannala; William Pavlicek; Michael D Crowell; Douglas O Faigel
Journal:  World J Gastroenterol       Date:  2015-02-14       Impact factor: 5.742

7.  Radiation dose to patients during endoscopic retrograde cholangiopancreatography.

Authors:  Jaume Boix; Vicente Lorenzo-Zúñiga
Journal:  World J Gastrointest Endosc       Date:  2011-07-16

8.  Analysis of patients receiving ≥ 100 mSv during a computed tomography intervention.

Authors:  Ronald S Arellano; Kai Yang; Madan M Rehani
Journal:  Eur Radiol       Date:  2020-11-12       Impact factor: 5.315

9.  Patient radiation dose in diagnostic and interventional procedures for intracranial aneurysms: experience at a single center.

Authors:  Chang Woo Chun; Bum-Soo Kim; Cheol Hyoun Lee; Yon Kwon Ihn; Yong-Sam Shin
Journal:  Korean J Radiol       Date:  2014-11-07       Impact factor: 3.500

10.  Patient Radiation Exposure During Diagnostic and Therapeutic Procedures for Intracranial Aneurysms: A Multicenter Study.

Authors:  Yon Kwon Ihn; Bum-Soo Kim; Jun Soo Byun; Sang Hyun Suh; Yoo Dong Won; Deok Hee Lee; Byung Moon Kim; Young Soo Kim; Pyong Jeon; Chang-Woo Ryu; Sang-Il Suh; Dae Seob Choi; See Sung Choi; Jin Wook Choi; Hyuk Won Chang; Jae-Wook Lee; Sang Heum Kim; Young Jun Lee; Shang Hun Shin; Soo Mee Lim; Woong Yoon; Hae Woong Jeong; Moon Hee Han
Journal:  Neurointervention       Date:  2016-09-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.