Literature DB >> 15091266

Biomechanical analysis of fixation for vertically unstable sacroiliac dislocations with iliosacral screws and symphyseal plating.

H C Sagi1, N R Ordway, T DiPasquale.   

Abstract

OBJECTIVES: To examine the effects of various iliosacral screw configurations with and without symphyseal plating on sacroiliac (SI) motion and hemipelvis stability in the vertically unstable pelvic model.
DESIGN: Biomechanical, human cadaver.
SETTING: Level 1 trauma center. INTERVENTION: Hemipelvis and SI motion were analyzed on a Materials Testing System before and after creation of a vertically unstable APC III pelvic injury. Posterior fixation constructs consisted of iliosacral screws: (1). one into S1, (2). two into S1, or (3). one into S1 and one into S2. Results were obtained for all posterior constructs with and without a two-hole symphyseal plate. MAIN OUTCOME MEASUREMENT: Hemipelvis and SI motion with axial loading.
RESULTS: There was no statistically significant difference between one or two iliosacral screws when hemipelvis rotational or linear displacement was examined at the SI joint. The two-hole symphyseal plate significantly increased the stability of the fixation construct in resisting linear displacement in all three planes. Without the symphyseal plate, an abnormal loading response was seen at the SI joint, resulting in paradoxical posterior translation and sagittal plane rotation. The addition of the plate restored the normal response, and anterior rotation and translation were observed as in the intact state.
CONCLUSIONS: Anterior symphyseal plating for the vertically unstable hemipelvis significantly increases the stability of the fixation construct and restores the normal response of the hemipelvis to axial loading. A significant benefit to supplementary iliosacral screws in addition to a properly placed S1 iliosacral screw was not shown.

Entities:  

Mesh:

Year:  2004        PMID: 15091266     DOI: 10.1097/00005131-200403000-00002

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  28 in total

1.  Analysis of sacro-iliac joint screw fixation: does quality of reduction and screw orientation influence joint stability? A biomechanical study.

Authors:  Gaston Camino Willhuber; Ivan Zderic; Florian Gras; Dieter Wahl; Carlos Sancineto; Jorge Barla; Markus Windolf; Robert Geoff Richards; Boyko Gueorguiev
Journal:  Int Orthop       Date:  2015-10-05       Impact factor: 3.075

2.  Biomechanical comparison of three types of internal fixation in a type C zone II pelvic fracture model.

Authors:  Tao Wu; Wei Chen; Xu Li; Qi Zhang; Hong-Zhi Lv; Ying-Ze Zhang
Journal:  Int J Clin Exp Med       Date:  2015-02-15

3.  Functional outcome of unstable pelvic ring injuries after iliosacral screw fixation: single versus two screw fixation.

Authors:  S A Khaled; O Soliman; M A Wahed
Journal:  Eur J Trauma Emerg Surg       Date:  2014-10-21       Impact factor: 3.693

4.  [Posterior approaches to the pelvic ring].

Authors:  W Lehmann; L Großterlinden; J M Rueger
Journal:  Unfallchirurg       Date:  2013-03       Impact factor: 1.000

5.  Anterior internal fixator versus a femoral distractor and external fixation for sacroiliac joint compression and single stance gait testing: a mechanical study in synthetic bone.

Authors:  Jonathan M Vigdorchik; Amanda O Esquivel; Xin Jin; King H Yang; Rahul Vaidya
Journal:  Int Orthop       Date:  2013-05-04       Impact factor: 3.075

6.  Therapeutic effects of minimally invasive adjustable and locking compression plate for unstable pelvic fractures via posterior approach.

Authors:  Tao Wu; Wei Chen; Qi Zhang; Xu Li; Hong-Zhi Lv; Guang Yang; Ying-Ze Zhang
Journal:  Int J Clin Exp Med       Date:  2015-01-15

7.  Management of the open book APC II pelvis: Survey results from pelvic and acetabular surgeons in the United Kingdom.

Authors:  James R Gill; Colin Murphy; Ben Quansah; Andrew Carrothers
Journal:  J Orthop       Date:  2017-08-09

8.  Minimally invasive stabilisation of posterior pelvic ring instabilities with pedicle screws connected to a transverse rod.

Authors:  Hu Wang; Ya-Hui Fu; Chao Ke; Yan Zhuang; Kun Zhang; Xing Wei; Zhong Li; Jin-Lai Lei; Bin-Fei Zhang; Ping Liu
Journal:  Int Orthop       Date:  2017-12-14       Impact factor: 3.075

Review 9.  [Biomechanical principles for treatment of osteoporotic fractures of the pelvis].

Authors:  A Gänsslen
Journal:  Unfallchirurg       Date:  2010-04       Impact factor: 1.000

Review 10.  Vertical shear pelvic injury: evaluation, management, and fixation strategies.

Authors:  Laura Blum; Mark E Hake; Ryan Charles; Todd Conlan; David Rojas; Murphy Trey Martin; Cyril Mauffrey
Journal:  Int Orthop       Date:  2018-03-26       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.