Literature DB >> 15088727

The effect of flowable resin composites as gingival increments on the microleakage of posterior resin composites.

N Attar1, M D Turgut, H C Güngör.   

Abstract

Microleakage has been a major concern in restorative dentistry. The curing contraction of composites still presents a problem with controlling microleakage and postoperative sensitivity. This study investigated the effect of flowable materials on gingival microleakage of microhybrid and packable resin composite restorations. Ninety Class II cavities with cervical margins 1 mm below the CEJ were prepared in 45 extracted human premolars. The teeth were randomly divided into three groups (n=15). In each group, one side of each tooth was restored incrementally with respective composites-SureFil, Filtek P60 and Tetric Ceram; whereas, on the other side, flowable materials-Dyract Flow, Filtek Flow or Tetric Flow-were placed respectively as a 1-mm thick gingival increment before the resin composite restoration. The restored teeth were stored for one week in distilled water at 37 degrees C, thermocycled between 5 degrees C and 55 degrees C and immersed in 0.5% basic fuchsin for 24 hours. Dye penetration was evaluated using a stereomicroscope at 10x magnification. The data were analyzed statistically by Kruskal-Wallis analysis of variance and Mann-Whitney U-tests. The effect of flowable increments on reducing the gingival microleakage was found to be statistically significant for all restorative materials tested (p<0.05).

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15088727

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  10 in total

1.  Clinical performance of a nanofilled resin composite with and without an intermediary layer of flowable composite: a 2-year evaluation.

Authors:  Sebastian Stefanski; Jan W V van Dijken
Journal:  Clin Oral Investig       Date:  2010-11-23       Impact factor: 3.573

Review 2.  Use of flowable resin composite as an intermediate layer in class II restorations: a systematic review and meta-analysis.

Authors:  Cleber Paradzinski Cavalheiro; Helena Scherer; José Carlos Pettorossi Imparato; Fabrício Mezzomo Collares; Tathiane Larissa Lenzi
Journal:  Clin Oral Investig       Date:  2021-08-27       Impact factor: 3.606

3.  Evaluation of gingival microleakage of class II resin composite restorations with fiber inserts: An in vitro study.

Authors:  Rs Basavanna; Anish Garg; Ravi Kapur
Journal:  J Conserv Dent       Date:  2012-04

Review 4.  Evaluation of Microleakage and Marginal Ridge Fracture Resistance of Primary Molars Restored with Three Restorative Materials: A Comparative in vitro Study.

Authors:  Tapan Satish Yeolekar; Nagalakshmi Ramesh Chowdhary; K S Mukunda; N K Kiran
Journal:  Int J Clin Pediatr Dent       Date:  2015-08-11

5.  The effect of three lining materials on microleakage of packable composite resin restorations in young premolars with cavity margins located on enamel and dentin/cementum - An In vitro study.

Authors:  Hazim Mohamed Rizk; Mohammed Al-Ruthea; Mohammed Ali Habibullah
Journal:  Int J Health Sci (Qassim)       Date:  2018 Nov-Dec

6.  Retrospective evaluation of the clinical performance of direct composite restorations using the snow-plow technique: Up to 4 years follow-up.

Authors:  Ailreza Borouziniat; Hossain Khaki; Sara Majidinia
Journal:  J Clin Exp Dent       Date:  2019-11-01

7.  Evaluation of microleakage in Class II composite restorations: Bonded-base and bulk-fill techniques.

Authors:  Atiyeh Feiz; Marzieh Sajedi; Niloufar Jafari; Edward J Swift
Journal:  Dent Res J (Isfahan)       Date:  2021-10-21

8.  Comparative in vitro evaluation of internal adaptation of resin-modified glass ionomer, flowable composite and bonding agent applied as a liner under composite restoration: A scanning electron microscope study.

Authors:  M Soubhagya; K Mallikarjun Goud; B S Deepak; Sophia Thakur; T N Nandini; J Arun
Journal:  J Int Oral Health       Date:  2015-04

9.  Marginal sealing ability of silorane and methacrylate resin composites in class II cavities: A scanning electron microscopic study.

Authors:  Jyothi Kashi Nanjundasetty; Soumyaranjan Nanda; Venugopal Panuganti; Jayashankar Chatra Marigowda
Journal:  J Conserv Dent       Date:  2013-11

10.  Evaluation of Microleakage in Class II Cavities using Packable Composite Restorations with and without use of Liners.

Authors:  Rajesh Arora; Ravi Kapur; Nikhil Sibal; Sumit Juneja
Journal:  Int J Clin Pediatr Dent       Date:  2012-12-05
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.