Use of automatic threshold tracking function with non-low polarization leads: risk for algorithm malfunction.

David Luria1, Osnat Gurevitz, David Bar Lev, Yana Tkach, Michael Eldar, Michael Glikson.   

Abstract

The AutoCapture (AC) function of new pacemakers (PM) from St Jude Medical (SJM) was originally recommended for use with low polarization (LP) ventricular leads only.However, recent reports have encouraged the use of the AC function with various leads, including those lacking a special LP design. The objective of this study was to analyze the reliability and safety of the AC algorithm application with different types of pacing leads. The study group comprised 30 consecutive patients with AC PMs connected to three different types of non-LP leads. Ten patients with SJM LP leads served as the control group. The study protocol included a complete AC function test using four different pulse widths (PW). The pacing threshold was independently assessed by a manual/semiautomatic check. Erratic behavior of polarization measurements with increasing PWs was demonstrated in 43% (n = 13) of the study group. Invalid polarization measurements resulted in erroneous algorithm recommendation to apply AC function in 17% (n = 5) of the study patients. Subsequent AC function activation lead to incorrect threshold determination due to missed noncapture in three patients. AC function should be applied with caution with non-LP leads. "Off label" use of these leads may cause erroneous polarization signal measurements which, in some cases, may result in incorrect pacing threshold determination, rendering a potential risk to dependent patients.

Entities:  

Mesh:

Year:  2004        PMID: 15078397     DOI: 10.1111/j.1540-8159.2004.00463.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  Algorithm for ventricular capture verification based on the mechanical evoked response.

Authors:  E Yaacoby; S Akselrod; M Eldar; M Glikson
Journal:  Med Biol Eng Comput       Date:  2005-07       Impact factor: 2.602

2.  Failure of automatic capture verification in an epicardial pacemaker system.

Authors:  Leonardo Liberman; Allan J Hordof; Daphne S Hsu; Robert H Pass
Journal:  J Interv Card Electrophysiol       Date:  2005-09       Impact factor: 1.900

3.  Automatic atrial capture device control in real-life practice: A multicenter experience.

Authors:  Massimo Giammaria; Gianluca Quirino; Mariangela Alberio; Umberto Parravicini; Eliana Cipolla; Guido Rossetti; Antonio Ruocco; Gaetano Senatore; Francesco Rametta; Paolo Pistelli
Journal:  J Arrhythm       Date:  2016-07-11

4.  Hemodynamic Surveillance of Ventricular Pacing Effectiveness with the Transvalvular Impedance Sensor.

Authors:  Valeria Calvi; Giovanni Pizzimenti; Marco Lisi; Giuseppe Doria; Ludovico Vasquez; Francesco Lisi; Salvatore Felis; Donatella Tempio; Alfredo Virgilio; Alberto Barbetta; Franco Di Gregorio
Journal:  Adv Med       Date:  2014-08-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.