Literature DB >> 15073247

CT attenuation correction for myocardial perfusion quantification using a PET/CT hybrid scanner.

Pascal Koepfli1, Thomas F Hany, Christophe A Wyss, Mehdi Namdar, Cyrill Burger, Alexander V Konstantinidis, Thomas Berthold, Gustav K Von Schulthess, Philipp A Kaufmann.   

Abstract

UNLABELLED: In routine PET, a 10- to 20-min transmission scan with a rotating (68)Ge source is commonly obtained for attenuation correction (AC). AC is time-consuming using this procedure and could considerably be shortened by instead using a rapid CT scan. Our aim was to evaluate the feasibility of CT AC in quantitative myocardial perfusion PET using a hybrid PET/CT scanner.
METHODS: (13)N-labeled NH(3) and PET were used to measure myocardial blood flow (MBF) (mL/min/g) at rest and during standard adenosine stress. In group 1 (n = 7), CT scans (0.5 s) of the heart area with different tube currents (10, 40, 80, and 120 mA) were compared with a standard (68)Ge transmission (20 min) and with no AC. In group 2 (n = 3), the repeatability of 8 consecutive CT scans at a tube current of 10 mA was assessed. In group 3 (n = 4), emission was preceded and followed by 3 CT scans (10 mA) and 1 (68)Ge scan for each patient. For reconstruction, filtered backprojection (FBP) was compared with iterative reconstruction (IT).
RESULTS: For group 1, no significant difference in mean MBF for resting and hyperemic scans was found when emission reconstructed with (68)Ge AC was compared with emission reconstructed with CT AC at any of the different tube currents. Only emission without any correction differed significantly from (68)Ge AC. For group 2, repeated measurements revealed a coefficient of variance ranging from 2% to 5% and from 2% to 6% at rest and at stress, respectively. For group 3, similar reproducibility coefficients (RC) for MBF were obtained when (68)Ge AC(FBP) was compared with (68)Ge AC(IT) (RC = 0.218) and when CT AC(FBP) was compared with CT AC(IT) (RC = 0.227). Even better reproducibility (lower RC) was found when (68)Ge AC(FBP) was compared with CT AC(FBP) (RC = 0.130) and when (68)Ge AC(IT) was compared with CT AC(IT) (RC = 0.146).
CONCLUSION: Our study shows that for the assessment of qualitative and quantitative MBF with a hybrid PET/CT scanner, the use of CT AC (with a tube current of 10 mA) instead of (68)Ge AC provides accurate results.

Entities:  

Mesh:

Year:  2004        PMID: 15073247

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  46 in total

1.  The new-generation positron emission tomography/computed tomography scanners: implications for cardiac imaging.

Authors:  Stephen L Bacharach
Journal:  J Nucl Cardiol       Date:  2004 Jul-Aug       Impact factor: 5.952

2.  Patient-centered imaging.

Authors:  E Gordon Depuey; John J Mahmarian; Todd D Miller; Andrew J Einstein; Christopher L Hansen; Thomas A Holly; Edward J Miller; Donna M Polk; L Samuel Wann
Journal:  J Nucl Cardiol       Date:  2012-04       Impact factor: 5.952

Review 3.  PET: Is myocardial flow quantification a clinical reality?

Authors:  Antti Saraste; Sami Kajander; Chunlei Han; Sergey V Nesterov; Juhani Knuuti
Journal:  J Nucl Cardiol       Date:  2012-10       Impact factor: 5.952

4.  Impact of CT attenuation correction on the viability pattern assessed by 99mTc-tetrofosmin SPECT/ 18F-FDG PET.

Authors:  Rene Nkoulou; Aju P Pazhenkottil; Ronny R Buechel; Lars Husmann; Ines Valenta; Bernhard A Herzog; Mathias Wolfrum; Jelena R Ghadri; Philipp A Kaufmann
Journal:  Int J Cardiovasc Imaging       Date:  2010-10-08       Impact factor: 2.357

5.  Computed tomographic imaging within nuclear cardiology.

Authors: 
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

6.  President's message: Advocacy for nuclear cardiology--the self-referral issue.

Authors:  Kim A Williams
Journal:  J Nucl Cardiol       Date:  2004 Nov-Dec       Impact factor: 5.952

7.  Attenuation correction in cardiac SPECT: the boy who cried wolf?

Authors:  Guido Germano; Piotr J Slomka; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

Review 8.  PET/CT Myocardial Perfusion Imaging Acquisition and Processing: Ten Tips and Tricks to Help You Succeed.

Authors:  Talal Alnabelsi; Akanksha Thakkar; Ahmed Ibrahim Ahmed; Yushui Han; Mouaz H Al-Mallah
Journal:  Curr Cardiol Rep       Date:  2021-03-11       Impact factor: 2.931

9.  Protocol for measuring myocardial blood flow by PET/CT in cats.

Authors:  Simone D Jenni; Tiziano Schepis; Rolf Jenni; Patrick T Siegrist; Philipp A Kaufmann; Tony M Glaus
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-09-26       Impact factor: 9.236

10.  Coronary calcium score scans for attenuation correction of quantitative PET/CT 13N-ammonia myocardial perfusion imaging.

Authors:  Nina Burkhard; Bernhard A Herzog; Lars Husmann; Aju P Pazhenkottil; Irene A Burger; Ronny R Buechel; Ines Valenta; Christophe A Wyss; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-09-23       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.