Literature DB >> 1507294

Effect of increased intra-abdominal pressure on hepatic arterial, portal venous, and hepatic microcirculatory blood flow.

L N Diebel1, R F Wilson, S A Dulchavsky, J Saxe.   

Abstract

The effects of increased intra-abdominal pressure (IAP) on hepatic perfusion were studied in five anesthetized pigs. Doppler flow probes were used to measure hepatic artery blood flow (HABF) and portal venous blood flow (PVBF), and laser Doppler flowmetry was used to assess changes in hepatic microvascular blood flow (HMVBF). Hepatic blood flow responses to 10, 20, 30 and 40 mm Hg increases in IAP were assessed while the mean arterial BP (MAP) was maintained at baseline levels with IV crystalloid infusions. Although cardiac output and MAP were normal, HABF and HMVBF fell significantly with 10 mm IAP, and at 20 mm Hg IAP, HABF was 45% of the control value, PVBF was 65% of the control value, and HMVBF was 71% of the control value (p less than 0.05). At 30 and 40 mm Hg, hepatic blood flow was reduced even more. Thus, modest increases in IAP can cause significant impairment of hepatic perfusion despite a normal BP and cardiac output.

Entities:  

Mesh:

Year:  1992        PMID: 1507294     DOI: 10.1097/00005373-199208000-00019

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  81 in total

1.  Accuracy and effectiveness of laparoscopic vs open hepatic radiofrequency ablation.

Authors:  D J Scott; W N Young; L M Watumull; G Lindberg; J B Fleming; J F Huth; R V Rege; D R Jeyarajah; D B Jones
Journal:  Surg Endosc       Date:  2001-02       Impact factor: 4.584

2.  Does ischemia occur during laparoscopic cholecystectomy?

Authors:  C Polat; S Yilmaz; O Gökçe
Journal:  Surg Endosc       Date:  2003-06-13       Impact factor: 4.584

Review 3.  Regulation of hepatic blood flow: the hepatic arterial buffer response revisited.

Authors:  Christian Eipel; Kerstin Abshagen; Brigitte Vollmar
Journal:  World J Gastroenterol       Date:  2010-12-28       Impact factor: 5.742

4.  Effects of prolonged increased intra-abdominal pressure on gastrointestinal blood flow in pigs.

Authors:  F F Gudmundsson; H G Gislason; A Dicko; A Horn; A Viste; K Grong; K Svanes
Journal:  Surg Endosc       Date:  2001-05-07       Impact factor: 4.584

Review 5.  [Abdominal compartment syndrome: significance, diagnosis and treatment].

Authors:  A Schachtrupp; M Jansen; P Bertram; R Kuhlen; V Schumpelick
Journal:  Anaesthesist       Date:  2006-06       Impact factor: 1.041

Review 6.  Abdominal compartment syndrome.

Authors:  T Bin Saleem; I Ahmed
Journal:  Ir J Med Sci       Date:  2006 Jan-Mar       Impact factor: 1.568

7.  Microsphere intestinal blood flow analysis during pneumoperitoneum using carbon dioxide and helium.

Authors:  D Goitein; P Papasavas; W Yeaney; D Gagne; F Hayetian; P Caushaj; R Keenan; R Landreneau
Journal:  Surg Endosc       Date:  2005-03-08       Impact factor: 4.584

8.  Insufflation profile and body position influence portal venous blood flow during pneumoperitoneum.

Authors:  C N Gutt; C G Schmedt; T Schmandra; O Heupel; P Schemmer; M W Büchler
Journal:  Surg Endosc       Date:  2003-11-06       Impact factor: 4.584

9.  Prospective evaluation of vacuum-assisted fascial closure after open abdomen: planned ventral hernia rate is substantially reduced.

Authors:  Preston R Miller; J Wayne Meredith; James C Johnson; Michael C Chang
Journal:  Ann Surg       Date:  2004-05       Impact factor: 12.969

10.  Intra-abdominal pressure measurement using a modified nasogastric tube: description and validation of a new technique.

Authors:  M Sugrue; M D Buist; A Lee; D J Sanchez; K M Hillman
Journal:  Intensive Care Med       Date:  1994-11       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.