Validation of fractional moving blood volume measurement with power Doppler ultrasound in an experimental sheep model.

E Hernandez-Andrade1, T Jansson, D Ley, M Bellander, M Persson, G Lingman, K Marsál.   

Abstract

OBJECTIVE: To compare fractional moving blood volume (FMBV) estimation using power Doppler ultrasound (PDU) with blood flow estimation using radioactive microspheres (RMS) for evaluation of fetal organ blood perfusion.
METHODS: Blood flow was measured in the adrenal gland of nine exteriorized fetal lambs. Five fetal lambs underwent total umbilical cord occlusion in order to induce changes in the adrenal blood flow (asphyxia group). Four lambs were used as sham controls (control group). Three RMS injections, with coincident PDU recordings of the adrenal gland, were performed in each lamb. In the asphyxia group, measurements were taken before the cord occlusion, 5 min later and when the mean blood pressure decreased below 25 mmHg. In the control group, the measurements were done with an interval of 5 min. FMBV normalized for attenuation of PDU signals, and mean pixel intensity (MPI) were estimated offline. After completion of the study, adrenal blood perfusion was calculated according to the reference sample microsphere technique, using the isotope activity and expressed in mL/min/100 g. The correlation between RMS and FMBV and MPI, respectively, was analyzed individually for each lamb.
RESULTS: In the asphyxia group, all lambs showed a marked reduction in the adrenal blood perfusion towards the third RMS injection. In the control group, the adrenal perfusion showed small variations throughout the experiment. In the total material, there was a higher correlation between FMBV and RMS (median, r = 0.90; range, 0.43-0.99) than between MPI and RMS (median, r = 0.55; range, -0.53 to 0.99).
CONCLUSION: The FMBV method of quantifying PDU signals correlates highly with blood flow perfusion estimation using RMS in the fetal lamb adrenal gland. Copyright 2004 ISUOG.

Entities:  

Mesh:

Year:  2004        PMID: 15065186     DOI: 10.1002/uog.1002

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  6 in total

1.  Perfusion dynamics assessment with Power Doppler ultrasound in skeletal muscle during maximal and submaximal cycling exercise.

Authors:  H M Heres; T Schoots; B C Y Tchang; M C M Rutten; H M C Kemps; F N van de Vosse; R G P Lopata
Journal:  Eur J Appl Physiol       Date:  2018-03-22       Impact factor: 3.078

2.  Three-dimensional US Fractional Moving Blood Volume: Validation of Renal Perfusion Quantification.

Authors:  Alec W Welsh; J Brian Fowlkes; Stephen Z Pinter; Kimberly A Ives; Gabe E Owens; Jonathan M Rubin; Oliver D Kripfgans; Pádraig Looney; Sally L Collins; Gordon N Stevenson
Journal:  Radiology       Date:  2019-10-01       Impact factor: 11.105

3.  Applying spatial-temporal image correlation to the fetal kidney: Repeatability of 3D segmentation and volumetric impedance indices.

Authors:  Bonita Gu; Gordon N Stevenson; Ana Ferreira; Sudeshni Pathirana; Jennifer Sanderson; Amanda Henry; Jennifer Alphonse; Alec W Welsh
Journal:  Australas J Ultrasound Med       Date:  2018-05-11

4.  Novel spatial-temporal image correlation derived indices of tissue vascular impedance: A variability study.

Authors:  Linda Wu; Ana Ferreira; Gordon N Stevenson; Jennifer Sanderson; Aditi Mahajan; Neama Meriki; Alec W Welsh
Journal:  Australas J Ultrasound Med       Date:  2017-07-11

5.  Ultrasonographic tissue perfusion analysis at implant and palatal donor sites following soft tissue augmentation: A clinical pilot study.

Authors:  Lorenzo Tavelli; Shayan Barootchi; Jad Majzoub; Hsun-Liang Chan; William V Giannobile; Hom-Lay Wang; Oliver D Kripfgans
Journal:  J Clin Periodontol       Date:  2021-02-03       Impact factor: 8.728

6.  3D fractional moving blood volume (3D-FMBV) demonstrates decreased first trimester placental vascularity in pre-eclampsia but not the term, small for gestation age baby.

Authors:  Sally L Collins; Alec W Welsh; Lawrence Impey; J Alison Noble; Gordon N Stevenson
Journal:  PLoS One       Date:  2017-06-01       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.