Literature DB >> 15062938

Detection of small degree of nonuniformity in dialysate flow in hollow-fiber dialyzer using proton magnetic resonance imaging.

T Osuga1, T Obata, H Ikehira.   

Abstract

A small degree of nonuniformity in dialysate flow in a hollow-fiber dialyzer was detected using proton magnetic resonance imaging (MRI). Since paramagnetic ions reduce the spin-lattice relaxation time of protons around them, MRI can detect Gd in water. An aqueous solution of a chelate compound of Gd was impulsively injected into the dialysate flow path at a flow rate of 500 cm(3) /m, which is that utilized in actual dialysis. Despite the apparent elimination of Gd from the dialysate flow path by the newly injected dialysate fluid after the injection of Gd was terminated, MRI revealed that Gd remained in the interior of the hollow fiber. The observed structure pattern of the Gd concentration profile revealed that the dialysate flow had a small degree of nonuniformity despite the currently established design to restrict channeling in dialysate flow. Local nonuniformity of the hollow-fiber density and vortex generation in the dialysate flow were considered to cause the nonuniformity in the dialysate flow.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15062938     DOI: 10.1016/j.mri.2003.08.008

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  5 in total

1.  Experimental evaluation of flow and dialysis performance of hollow-fiber dialyzers with different packing densities.

Authors:  Ayaka Hirano; Shoko Kida; Ken-ichiro Yamamoto; Kiyotaka Sakai
Journal:  J Artif Organs       Date:  2011-11-25       Impact factor: 1.731

2.  A positron emission tomography approach to visualize flow perfusion in hollow-fiber membrane bioreactors.

Authors:  Davod Mohebbi-Kalhori
Journal:  J Artif Organs       Date:  2011-07-15       Impact factor: 1.731

3.  Relative diffusion of paramagnetic metal complexes of MRI contrast agents in an isotropic hydrogel medium.

Authors:  Bimali Sanjeevani Weerakoon; Toshiaki Osuga
Journal:  Radiol Phys Technol       Date:  2016-08-17

4.  Semipermeable Hollow Fiber Phantoms for Development and Validation of Perfusion-Sensitive MR Methods and Signal Models.

Authors:  J R Anderson; J J H Ackerman; J R Garbow
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2011-08       Impact factor: 1.176

Review 5.  Application of mathematical analysis on dialysis.

Authors:  Takehiro Miyasaka; Kiyotaka Sakai
Journal:  J Artif Organs       Date:  2022-09-10       Impact factor: 1.385

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.