Literature DB >> 15058176

An evaluation of three implant level impression techniques for single tooth implant.

M Firas Daoudi1, Derrick J Setchell, Lloyd J Searson.   

Abstract

This laboratory study investigated the hypotheses that there is no difference between three implant level impression techniques using vinyl polysiloxane impression material. The tested techniques were 1)- the repositioning technique. 2)-The pickup technique. 3)- The pickup technique with the impression copings splinted to the impression trays with autopolymerising acrylic resin. The Reflex Microscope was used for 3D measurement of distances and angles. Analysis of variance and Tukey's multiple comparisons test were applied to analyse the data. The results showed significant differences in implant analogue position with the repositioning and the pickup (unsplinted) impression techniques from the master model. Alarming rotational errors were recorded with the repositioning and the pickup (unsplinted) techniques. However, connecting the impression coping to the impression tray improves the accuracy of the pickup impression technique.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15058176

Source DB:  PubMed          Journal:  Eur J Prosthodont Restor Dent        ISSN: 0965-7452


  6 in total

1.  Evaluation of impression accuracy for a four-implant mandibular model--a digital approach.

Authors:  Michael Stimmelmayr; Kurt Erdelt; Jan-Frederik Güth; Arndt Happe; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-10-19       Impact factor: 3.573

Review 2.  Passive Fit in Screw Retained Multi-unit Implant Prosthesis Understanding and Achieving: A Review of the Literature.

Authors:  Muaiyed Mahmoud Buzayan; Norsiah Binti Yunus
Journal:  J Indian Prosthodont Soc       Date:  2013-12-28

3.  Clinical study evaluating the discrepancy of two different impression techniques of four implants in an edentulous jaw.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Arndt Happe; Markus Schlee; Florian Beuer
Journal:  Clin Oral Investig       Date:  2012-12-06       Impact factor: 3.573

4.  Effect of different impression materials and techniques on the dimensional accuracy of implant definitive casts.

Authors:  Behnaz Ebadian; Mansor Rismanchian; Badrosadat Dastgheib; Farshad Bajoghli
Journal:  Dent Res J (Isfahan)       Date:  2015 Mar-Apr

5.  Effect of Polyvinyl Siloxane Viscosity on Accuracy of Dental Implant Impressions.

Authors:  Ahmad Ghahremanloo; Mahdieh Seifi; Jalil Ghanbarzade; Seyyed Mohammad Abrisham; Rashid Abdolah Javan
Journal:  J Dent (Tehran)       Date:  2017-01

6.  Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study).

Authors:  Enas A Elshenawy; Ahmed M Alam-Eldein; Fadel A Abd Elfatah
Journal:  Int J Implant Dent       Date:  2018-03-20
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.