Literature DB >> 15058117

Bispectral index during modified rapid sequence induction using thiopentone or propofol and rocuronium.

M Y Sie1, P K Goh, L Chan, S Y Ong.   

Abstract

This randomized controlled trial compared Bispectral Index (BIS) values in 40 patients after a modified rapid sequence induction using thiopentone 4 mg/kg or propofol 2 mg/kg with rocuronium 0.6 mg/kg as muscle relaxant. Endotracheal intubation was performed at 60 seconds from induction of anaesthesia and BIS values were recorded for three minutes after induction. At the 120, 150 and 180 second measurements there was a significantly greater proportion of subjects with BIS values < or = 60 ("anaesthetized") in the propofol group compared with the thiopentone group (P values < 0.02, < 0.01 and < 0.01 respectively). All intubations were completed within two minutes. No explicit recall of intubation was detected clinically with either induction agent. The BIS scores we have measured suggest that thiopentone 4 mg/kg is more likely to be associated with lighter planes of anaesthesia and consequent risk of awareness than propofol 2 mg/kg, if intubation is delayed or prolonged.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15058117     DOI: 10.1177/0310057X0403200104

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  5 in total

1.  Effect of rocuronium on the bispectral index under anesthesia and tracheal intubation.

Authors:  Hui Yue; Jinyu Han; Ling Liu; Kaiyuan Wang; Jincheng Li
Journal:  Exp Ther Med       Date:  2016-10-20       Impact factor: 2.447

Review 2.  Induction of anaesthesia: a guide to drug choice.

Authors:  Nathalie Nathan; Isabelle Odin
Journal:  Drugs       Date:  2007       Impact factor: 9.546

3.  [Depth of anaesthesia during intubation: comparison between propofol and thiopentone].

Authors:  C E Beck; B Pohl; M Janda; J Bajorat; R Hofmockel
Journal:  Anaesthesist       Date:  2006-04       Impact factor: 1.041

4.  Does a single dose of intravenous nicardipine or nimodipine affect the bispectral index following rapid sequence intubation?

Authors:  Jeong Jin Lee; Jie Ae Kim; Hyun Joo Ahn; Jin-Kyoung Kim; Mikyung Yang; Soo Joo Choi; Hyun-Soo Kim; Soo Hyun Yang
Journal:  Korean J Anesthesiol       Date:  2010-10-21

5.  Intravenous lidocaine does not affect the anesthetic depth during rapid sequence induction and intubation as assessed by Bispectral Index monitoring: a randomized double blind study.

Authors:  Chryssoula Staikou; Anteia Paraskeva; Iosifina Karmaniolou; Antonis Vezakis; Athanasia Tsaroucha
Journal:  Arch Med Sci       Date:  2013-08-08       Impact factor: 3.318

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.