Literature DB >> 15057098

Failure of capsular enhanced short external rotator repair after total hip replacement.

Thomas Stähelin1, Lisca Drittenbass, Otmar Hersche, Wolfgang Miehlke, Urs Munzinger.   

Abstract

The failure rate of repaired short external rotator muscles was determined in 20 total hip replacements done in 19 patients. The piriformis, both obturator and gemellus muscles, and the capsule were released close to the femur in a single flap leaving the tendon-capsule junction intact. After implantation of the prosthetic components, the flap was transosseously reattached with three grasping stitches, each encompassing the entire tendon-capsule junction. Radiopaque markers were attached to each side of the suture. The distance between markers was measured intraoperatively and then determined on radiographs 1 day and 3 months postoperatively; 25 mm or more and at least double the distance measured intraoperatively indicated failure. In 15 of the 20 hips the repair failed; in three hips the repaired flap was pulled out within the first day, and in 12, within 3 months. Capsular enhanced repairs of the short extensor rotator muscles, using the technique described, largely are unable to withstand forces that occur at the site of repair during the healing process. The quality of other repair techniques should be determined to identify superior techniques.

Entities:  

Mesh:

Year:  2004        PMID: 15057098     DOI: 10.1097/00003086-200403000-00028

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  18 in total

1.  Minimally invasive total hip arthroplasty using a transpiriformis approach: a preliminary report.

Authors:  Douglas J Roger; David Hill
Journal:  Clin Orthop Relat Res       Date:  2012-01-04       Impact factor: 4.176

2.  Surgical technique: a simple soft-tissue-only repair of the capsule and external rotators in posterior-approach THA.

Authors:  James A Browne; Mark W Pagnano
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

3.  Emerging ideas: soft tissue applications of radiostereometric analysis.

Authors:  Lucian B Solomon; Stuart A Callary
Journal:  Clin Orthop Relat Res       Date:  2010-11-23       Impact factor: 4.176

Review 4.  [Minimally invasive total hip arthroplasty. Anterior approach].

Authors:  F Rachbauer
Journal:  Orthopade       Date:  2006-07       Impact factor: 1.087

5.  [Abductor repair failure and nerve damage during hip replacement via the transgluteal approach. Why less invasive methods of joint replacement are needed, and some approaches to solving the problems].

Authors:  T Stähelin
Journal:  Orthopade       Date:  2006-12       Impact factor: 1.087

6.  The capsule's contribution to total hip construct stability--a finite element analysis.

Authors:  Jacob M Elkins; Nicholas J Stroud; M James Rudert; Yuki Tochigi; Douglas R Pedersen; Benjamin J Ellis; John J Callaghan; Jeffrey A Weiss; Thomas D Brown
Journal:  J Orthop Res       Date:  2011-04-14       Impact factor: 3.494

7.  Modified posterior approach to total hip arthroplasty to enhance joint stability.

Authors:  Yong Sik Kim; Soon Yong Kwon; Doo Hoon Sun; Suk Ku Han; William J Maloney
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

8.  Review: posterior soft tissue repair in primary total hip arthroplasty.

Authors:  F Bottner; P M Pellicci
Journal:  HSS J       Date:  2006-02

9.  Posterior Soft Tissue Repair After Primary THA is Durable at Mid-term Followup: A Prospective MRI Study.

Authors:  Alexander S McLawhorn; Hollis G Potter; Michael B Cross; Friedrich Boettner; Weiyang Lim; Yuo-yu Lee; Paul M Pellicci
Journal:  Clin Orthop Relat Res       Date:  2015-06-06       Impact factor: 4.176

10.  MRI shows biologic restoration of posterior soft tissue repairs after THA.

Authors:  Paul M Pellicci; Hollis G Potter; Li F Foo; Friedrich Boettner
Journal:  Clin Orthop Relat Res       Date:  2008-09-24       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.