E Schäfer1, M Vlassis. 1. Department of Operative Dentistry, University of Münster, Münster, Germany. eschaf@uni-muenster.de
Abstract
AIM: To compare the shaping ability of ProTaper with Reamer with Alternating Cutting Edges (RaCe) instruments. Part 1 of this two-part report describes the efficacy of these two nickel-titanium instruments in simulated curved root canals. METHODOLOGY: Simulated canals with 28 degrees and 35 degrees curves in resin blocks were prepared with ProTaper and RaCe instruments using a crown-down preparation technique (n = 24 canals in each case). Pre- and postinstrumentation images were recorded, and assessment of canal shape was completed with a computer image analysis program. Material removal was measured at 20 measuring points, beginning 1 mm from the apex. Incidence of canal aberrations, preparation time, changes of working length and instrument failures were also recorded. The data were analysed statistically using the Mann-Whitney U-test or the chi-square test. RESULTS: On average, canals prepared with RaCe instruments remained better centred compared with those enlarged with ProTaper files. Three RaCe instruments and two ProTaper files fractured during preparation (P > 0.05). Between both the canal types, RaCe was significantly faster (P < 0.001) than ProTaper and maintained working length significantly better (P < 0.05). CONCLUSION: Both instruments prepared curved canals rapidly and were relatively safe. RaCe respected original canal curvature better than ProTaper, which tended to transport towards the outer aspect of the curve.
AIM: To compare the shaping ability of ProTaper with Reamer with Alternating Cutting Edges (RaCe) instruments. Part 1 of this two-part report describes the efficacy of these two nickel-titanium instruments in simulated curved root canals. METHODOLOGY: Simulated canals with 28 degrees and 35 degrees curves in resin blocks were prepared with ProTaper and RaCe instruments using a crown-down preparation technique (n = 24 canals in each case). Pre- and postinstrumentation images were recorded, and assessment of canal shape was completed with a computer image analysis program. Material removal was measured at 20 measuring points, beginning 1 mm from the apex. Incidence of canal aberrations, preparation time, changes of working length and instrument failures were also recorded. The data were analysed statistically using the Mann-Whitney U-test or the chi-square test. RESULTS: On average, canals prepared with RaCe instruments remained better centred compared with those enlarged with ProTaper files. Three RaCe instruments and two ProTaper files fractured during preparation (P > 0.05). Between both the canal types, RaCe was significantly faster (P < 0.001) than ProTaper and maintained working length significantly better (P < 0.05). CONCLUSION: Both instruments prepared curved canals rapidly and were relatively safe. RaCe respected original canal curvature better than ProTaper, which tended to transport towards the outer aspect of the curve.
Authors: Gopal S Narayan; Sokkalingam Mothilal Venkatesan; C S Karumaran; Rajamani Indira; S Ramachandran; M R Srinivasan Journal: Contemp Clin Dent Date: 2012-09
Authors: Emilio Carlos Sponchiado Júnior; Tiago Silva da Fonseca; Matheus Franco da Frota; Fredson Marcio Acris de Carvalho; André Augusto Franco Marques; Lucas da Fonseca Roberti Garcia Journal: Contemp Clin Dent Date: 2014-04