Literature DB >> 24676579

Apical transportation associated with ProTaper Universal F1, F2 and F3 instruments in curved canals prepared by undergraduate students.

Manoel Brito-Júnior1, André Luis Faria-E-Silva2, Carla Cristina Camilo1, Rodrigo Dantas Pereira3, Neilor Mateus Antunes Braga4, Manoel Damião Sousa-Neto5.   

Abstract

OBJECTIVE: This study evaluated apical transportation associated with ProTaper Universal Fl, F2 and F3 rotary files in curved canais prepared by undergraduate students.
MATERIAL AND METHODS: Twenty mesial roots of mandibular molars with curvatures ranging between 25° and 35° were selected. Mesiobuccal canals were instrumented by twenty students with the ProTaper system (Dentsply-Maillefer, Ballaigues, Switzerland) according to the manufacturer's instructions. Pre-fiaring was performed with Sl and SX files. A #15 K-file was inserted into the root canal up to the working length (WL), and an initial digital radiograph was taken in a buccolingual direction (baseline). Afterwards, the S1, S2, F1, F2, and F3 files were employed up to the WL. Other radiographies were taken in the same orientation of the baseline after the use of the Fl, F2, and F3 files, with each file inserted into the root canal. The radiographic images were overlapped, and the Image J software was used to measure the distance between the rotary files' ends and the #15 K-file's end, characterizing the apical transportation. Data were analyzed by Repeated Measure ANOVA and by the SNK post hoc test (P<0.05).
RESULTS: It was verified that file size affected apical transportation significantly (P<0.001). The F3 file showed higher apical transportation than Fl and F2, while between these last files there was no difference.
CONCLUSION: The undergraduate students produced lower apical transportation in curved canals when they did not use the F3 rotary file.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24676579      PMCID: PMC3956400          DOI: 10.1590/1678-775720130464

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


  28 in total

1.  Assessing apical transportation in curved canals: comparison between cross-sections and micro-computed tomography.

Authors:  Laila Gonzales Freire; Giulio Gavini; Rodrigo Sanches Cunha; Marcelo dos Santos
Journal:  Braz Oral Res       Date:  2012 May-Jun

2.  Histological evaluation of the effectiveness of increased apical enlargement for cleaning the apical third of curved canals.

Authors:  V J Fornari; Y T C Silva-Sousa; J R Vanni; J D Pécora; M A Versiani; M D Sousa-Neto
Journal:  Int Endod J       Date:  2010-08-16       Impact factor: 5.264

3.  Micro-computed tomographic comparison of nickel-titanium rotary versus traditional instruments in C-shaped root canal system.

Authors:  Xingzhe Yin; Gary Shun-Pan Cheung; Chengfei Zhang; Yoshiko Murakami Masuda; Yuichi Kimura; Koukichi Matsumoto
Journal:  J Endod       Date:  2010-04       Impact factor: 4.171

4.  The effect of apical preparation size on irrigant flow in root canals evaluated using an unsteady Computational Fluid Dynamics model.

Authors:  C Boutsioukis; C Gogos; B Verhaagen; M Versluis; E Kastrinakis; L W M Van der Sluis
Journal:  Int Endod J       Date:  2010-07-05       Impact factor: 5.264

5.  Hand and nickel-titanium root canal instrumentation performed by dental students: a micro-computed tomographic study.

Authors:  M Peru; C Peru; F Mannocci; M Sherriff; L S Buchanan; T R Pitt Ford
Journal:  Eur J Dent Educ       Date:  2006-02       Impact factor: 2.355

6.  Comparison of canal transportation and changes in canal curvature of two nickel-titanium rotary instruments.

Authors:  Kariem M El Batouty; Waleed E Elmallah
Journal:  J Endod       Date:  2011-07-13       Impact factor: 4.171

7.  Flexibility of K3 and ProTaper universal instruments.

Authors:  Renata Grazziotin-Soares; Flares Barato Filho; José Roberto Vanni; Susimara Almeida; Elias Pandonor Motcy de Oliveira; Fernando Branco Barletta; Orlando Limongi
Journal:  Braz Dent J       Date:  2011

8.  CT evaluation of apical canal transportation associated with stainless steel hand files, oscillatory technique and pro taper rotary system.

Authors:  Mateus Silveira Martins Hartmann; Vânia Regina Camargo Fontanella; José Roberto Vanni; Volmir João Fornari; Fernando Branco Barletta
Journal:  Braz Dent J       Date:  2011

9.  Effects of two nickel-titanium instrument systems, Mtwo versus ProTaper universal, on root canal geometry assessed by micro-computed tomography.

Authors:  Guobin Yang; Guohua Yuan; Xiaofei Yun; Xuedong Zhou; Bojin Liu; Hongkun Wu
Journal:  J Endod       Date:  2011-08-16       Impact factor: 4.171

10.  Root canal shaping using rotary nickel-titanium files in preclinical dental education in Turkey.

Authors:  Gül Çelik Ünal; Murat Maden; Ekim Onur Orhan; Erdal Sarıtekin; Anıl Teke
Journal:  J Dent Educ       Date:  2012-04       Impact factor: 2.264

View more
  2 in total

1.  Transportation and Centering Ability of Neoniti and ProTaper Instruments; A CBCT Assessment.

Authors:  Zahrasadat Madani; Ali Soleymani; Tasnim Bagheri; Ehsan Moudi; Ali Bijani; Vahid Rakhshan
Journal:  Iran Endod J       Date:  2017

2.  A comparative study of root canal shaping using protaper universal and protaper next rotary files in preclinical dental education.

Authors:  Gül Çelik; Feyza Özdemir Kısacık; Emir Faruk Yılmaz; Arife Mersinlioğlu; İhsan Furkan Ertuğrul; Hikmet Orhan
Journal:  PeerJ       Date:  2019-08-19       Impact factor: 2.984

  2 in total