Literature DB >> 15054554

Prospective analysis of percutaneous central venous catheterization in infants <4.0 kg undergoing cardiac surgery.

T Iwasaki1, Y Hayashi, Y Ohnishi, M Kuro.   

Abstract

Our previous study showed that the success rate of cannulation of the internal jugular vein (IJV) was significantly decreased in infants weighing less than 4.0 kg. We prospectively evaluated results of central venous catheterization in 101 infants weighing less than 4.0 kg undergoing cardiac surgery. The first attempt was routinely performed on the right IJV. If the first attempt failed, the anesthesiologist was free to choose the cannulation site. We examined the effects of patient weight and the experience of the anesthesiologist on successful central catheterization and efficacy of the external jugular vein (EJV) if the first attempt failed. The first right IJV cannulation was successful in 53 infants (52.5%) and the overall successful catheterization rate was 82.2%. Success rates of cannulation of the right IJV, left IJV, and EJV were 64, 13, and 6%, respectively. Body weight contributed significantly to successful catheterization, but the experience of the anesthesiologist did not. These results suggest that EJV cannulation improves the successful central catheterization in infants weighing less than 4.0 kg if IJV cannulation fails. Body weight of an infant, but not the experience of the anesthesiologist, contributed to successful catheterization in this patient population.

Entities:  

Mesh:

Year:  2004        PMID: 15054554     DOI: 10.1007/s00246-003-0643-8

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  7 in total

1.  Percutaneous catheterisation of the internal jugular vein.

Authors:  I C English; R M Frew; J F Pigott; M Zaki
Journal:  Anaesthesia       Date:  1969-10       Impact factor: 6.955

2.  Central vein catheterization. Failure and complication rates by three percutaneous approaches.

Authors:  J I Sznajder; F R Zveibil; H Bitterman; P Weiner; S Bursztein
Journal:  Arch Intern Med       Date:  1986-02

Review 3.  Monitoring during paediatric cardiac anaesthesia.

Authors:  J P Purday
Journal:  Can J Anaesth       Date:  1994-09       Impact factor: 5.063

4.  Internal jugular vein catheterization in infants undergoing cardiovascular surgery: an analysis of the factors influencing successful catheterization.

Authors:  Y Hayashi; O Uchida; O Takaki; Y Ohnishi; T Nakajima; H Kataoka; M Kuro
Journal:  Anesth Analg       Date:  1992-05       Impact factor: 5.108

5.  Preliminary experience with the Doppler ultrasound guided vascular access needle in paediatric patients.

Authors:  P A MacIntyre; G Samra; D J Hatch
Journal:  Paediatr Anaesth       Date:  2000       Impact factor: 2.556

6.  Central venous catheterization in infants and children with congenital heart diseases: experiences with 500 consecutive catheter placements.

Authors:  P Mitto; A Barankay; P Späth; R Kunkel; J A Richter
Journal:  Pediatr Cardiol       Date:  1992-01       Impact factor: 1.655

7.  Comparison of internal and external jugular cannulation of the central circulation in the pediatric patient.

Authors:  S C Nicolson; M F Sweeney; R A Moore; D R Jobes
Journal:  Crit Care Med       Date:  1985-09       Impact factor: 7.598

  7 in total
  2 in total

1.  Percutaneous central venous catheterization in infants < 4.0 kg.

Authors:  P Arnold; I Galvez
Journal:  Pediatr Cardiol       Date:  2005 Sep-Oct       Impact factor: 1.655

2.  A clinical rule for the difficulty prediction on scalp intravenous access in infants (SIAI) from emergency room.

Authors:  Fengqin Wei; Weiyu Chen; Xiaoti Lin
Journal:  Sci Rep       Date:  2020-04-20       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.