Literature DB >> 15050075

Volumetric evaluation of facial swelling utilizing a 3-D range camera.

E Yip1, A Smith, M Yoshino.   

Abstract

Quantitative analysis of facial volume is important in the assessment of facial swelling. Previous research has demonstrated that the Fiore trade mark light-structured 3-D range camera is a rapid, non-invasive, and safe imaging technology for the quantitative analysis of facial morphology. The development of the Rugle-3D trade mark volumetric measurement software programme has allowed for the development of a powerful imaging and measurement system. This study aimed to determine the accuracy and reproducibility of Fiore trade mark by measuring simulated facial swelling. A model involving 20 human subjects was devised to simulate facial swelling for image acquisition and measurement in order to assess the accuracy and reproducibility of the device. A systematic error of 1.25% and reproducibility of 3.27% was determined for the imaging system. It is concluded that Fiore trade mark is an accurate and reproducible technology that is sensitive and would be applicable to clinical studies of facial swelling.

Entities:  

Mesh:

Year:  2004        PMID: 15050075     DOI: 10.1054/ijom.2003.0501

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  5 in total

1.  3-D imaging and quantitative comparison of human dentitions and simulated bite marks.

Authors:  S A Blackwell; R V Taylor; I Gordon; C L Ogleby; T Tanijiri; M Yoshino; M R Donald; J G Clement
Journal:  Int J Legal Med       Date:  2006-01-04       Impact factor: 2.686

2.  About Face: Matching Unfamiliar Faces Across Rotations of View and Lighting.

Authors:  Simone Favelle; Harold Hill; Peter Claes
Journal:  Iperception       Date:  2017-11-29

3.  The Impact of Using Kinesio Tape on Non-Infectious Complications after Impacted Mandibular Third Molar Surgery.

Authors:  Aleksandra Jaroń; Olga Preuss; Elżbieta Grzywacz; Grzegorz Trybek
Journal:  Int J Environ Res Public Health       Date:  2021-01-06       Impact factor: 3.390

4.  Validation of a new three-dimensional imaging system using comparative craniofacial anthropometry.

Authors:  Farhad B Naini; Sarah Akram; Julia Kepinska; Umberto Garagiola; Fraser McDonald; David Wertheim
Journal:  Maxillofac Plast Reconstr Surg       Date:  2017-08-25

5.  Quality of Life of Patients after Kinesio Tape Applications Following Impacted Mandibular Third Molar Surgeries.

Authors:  Aleksandra Jaroń; Olga Preuss; Berenika Konkol; Grzegorz Trybek
Journal:  J Clin Med       Date:  2021-05-19       Impact factor: 4.241

  5 in total