Literature DB >> 15036024

Right ventricular myocardial activation delay in adult patients with right bundle branch block late after repair of Tetralogy of Fallot.

A D'Andrea1, P Caso, B Sarubbi, M D'Alto, M Giovanna Russo, M Scherillo, M Cotrufo, R Calabrò.   

Abstract

Electromechanical interaction, with prolonged QRS duration due to right ventricular (RV) overload, has been described as a predictor of unfavorable outcome in patients late after correction of Tetralogy of Fallot (TOF). Aim of our study was to evaluate myocardial function and activation delay of both left and right ventricles in TOF patients. Doppler echo, treadmill test and pulsed Tissue Doppler (TD) were performed in 25 healthy subjects and in 30 adult patients who had undergone surgery for TOF, all with right bundle branch block on ECG. Exclusion criteria were evidence of residual pulmonary either stenosis or regurgitation. By use of TD, the level of both LV mitral and RV tricuspid annulus were measured: systolic (Sm), early- and late-diastolic (Em and Am) regional peak velocities. The indexes of myocardial systolic activation were calculated: precontraction time (PCTm) and interventricular activation delay (InterV-del) (difference of PCTm between RV and LV segments). The two groups were comparable for LV diameters and for Doppler indexes, while QRS duration was prolonged and RV end-diastolic diameter was increased in TOF. By TD analysis, only at the level of tricuspid annulus TOF patients had lower Sm and Em, and increased RV PCTm ( p<0.001 ) and InterV-del ( p<0.0001 ), even after adjustment for heart rate (HR) and QRS duration. By treadmill test, TOF showed reduced cardiac functional reserve. In seven patients non-sustained ventricular tachycardia was documented during physical effort. By multivariate analysis, RV Em ( p<0.001 ), and InterV-del ( p<0.01 ) were independently associated to maximal workload at peak effort. The same InterV-del was an independent determinant of risk of ventricular arrhythmias during effort ( p<0.01 ). A cut-off point of Em peak velocity of tricuspid annulus <0.13 m/s at rest showed a sensitivity of 91% and a specificity of 88% in identifying TOF patients with submaximal exercise test. A cut-off point of InterV-del >55 ms showed 87% sensitivity and 88% specificity to detect increased risk of ventricular arrhythmias during effort. In TOF patients, TD analysis at rest may be taken into account as a non-invasive and easy-repeatable tool to predict cardiac performance during physical effort, and to select subgroups of patients at increased risk of ventricular arrhythmias.

Entities:  

Mesh:

Year:  2004        PMID: 15036024     DOI: 10.1016/S1525-2167(03)00053-2

Source DB:  PubMed          Journal:  Eur J Echocardiogr        ISSN: 1532-2114


  8 in total

1.  Differential strain and velocity generation along the right ventricular free wall in pulmonary hypertension.

Authors:  A López-Candales; N Rajagopalan; B Gulyasy; K Edelman; R Bazaz
Journal:  Can J Cardiol       Date:  2009-03       Impact factor: 5.223

Review 2.  Ventricular performance after surgery for a congenital heart defect as assessed using advanced echocardiography: from doppler flow to 3D echocardiography and speckle-tracking strain imaging.

Authors:  Liselotte M Klitsie; Arno A W Roest; Nico A Blom; Arend D J ten Harkel
Journal:  Pediatr Cardiol       Date:  2014-01       Impact factor: 1.655

3.  Delayed onset of tricuspid valve flow in repaired tetralogy of Fallot: an additional mechanism of diastolic dysfunction and interventricular dyssynchrony.

Authors:  Ai-Min Sun; Fahad AlHabshan; Michael Cheung; Gabriele Bronzetti; Andrew N Redington; Lee N Benson; Christopher Macgowan; Shi-Joon Yoo
Journal:  J Cardiovasc Magn Reson       Date:  2011-08-24       Impact factor: 5.364

4.  Prognostic value of intra-left ventricular electromechanical asynchrony in patients with mild hypertrophic cardiomyopathy compared with power athletes.

Authors:  A D'Andrea; P Caso; S Cuomo; G Salerno; R Scarafile; C Mita; G De Corato; B Sarubbi; M Scherillo; R Calabrò
Journal:  Br J Sports Med       Date:  2006-03       Impact factor: 13.800

5.  Molecular and physiological characterization of RV remodeling in a murine model of pulmonary stenosis.

Authors:  Takashi Urashima; Mingming Zhao; Roger Wagner; Giovanni Fajardo; Sara Farahani; Tom Quertermous; Daniel Bernstein
Journal:  Am J Physiol Heart Circ Physiol       Date:  2008-06-27       Impact factor: 4.733

6.  Right ventricular mechanics in hypertrophic cardiomyopathy using feature tracking.

Authors:  Hala Mahfouz Badran; Mahmood Soliman; Hesham Hassan; Raed Abdelfatah; Haythem Saadan; Magdi Yacoub
Journal:  Glob Cardiol Sci Pract       Date:  2013-11-01

7.  Evaluation of right ventricular function in operated tetralogy of Fallot patients with tissue Doppler imaging before and after pulmonary valve replacement.

Authors:  Hazım Alper Gürsu; Birgül Varan; İlkay Erdoğan; Murat Özkan
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2018-07-03       Impact factor: 0.332

8.  Improved cardiac MRI volume measurements in patients with tetralogy of Fallot by independent end-systolic and end-diastolic phase selection.

Authors:  Hendrik G Freling; Petronella G Pieper; Karin M Vermeulen; Jeroen M van Swieten; Paul E Sijens; Dirk J van Veldhuisen; Tineke P Willems
Journal:  PLoS One       Date:  2013-01-31       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.