Literature DB >> 15029916

Biomechanical comparison of anterior and posterior stabilization methods in atlantoaxial instability.

Sung-Min Kim1, T Jesse Lim, Josemaria Paterno, Tae-Jin Hwang, Kun-Woo Lee, Raju S V Balabhadra, Daniel H Kim.   

Abstract

OBJECT: The authors compared the biomechanical stability of two anterior fixation procedures--anterior C1-2 Harms plate/screw (AHPS) fixation and the anterior C1-2 transarticular screw (ATS) fixation; and two posterior fixation procedures--the posterior C-1 lateral mass combined with C-2 pedicle screw/rod (PLM/APSR) fixation and the posterior C1-2 transarticular screw (PTS) fixation after destabilization.
METHODS: Sixteen human cervical spine specimens (Oc-C3) were tested in three-dimensional flexion-extension, axial rotation, and lateral bending motions after destabilization by using an atlantoaxial C1-2 instability model. In each loading mode, moments were applied to a maximum of 1.5 Nm, and the range of motion (ROM), neutral zone (NZ), and elastic zone (EZ) were determined and values compared using the intact spine, the destabilized spine, and the postfixation spine. The AHPS method produced inferior biomechanical results in flexion-extension and lateral bending modes compared with the intact spine. The lateral bending NZ and ROM for this method differed significantly from the other three fixation techniques (p < 0.05), although statistically significant differences were not obtained for all other values of ROM and NZ for the other three procedures. The remaining three methods restored biomechanical stability and improved it over that of the intact spine.
CONCLUSIONS: The PLM/APSR fixation method was found to have the highest biomechanical stiffness followed by PTS, ATS, and AHPS fixation. The PLM/APSR fixation and AATS methods can be considered good procedures for stabilizing the atlantoaxial joints, although specific fixation methods are determined by the proper clinical and radiological characteristics in each patient.

Entities:  

Mesh:

Year:  2004        PMID: 15029916     DOI: 10.3171/spi.2004.100.3.0277

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  11 in total

1.  Anterior retropharyngeal fixation C1-2 for stabilization of atlantoaxial instabilities: study of feasibility, technical description and preliminary results.

Authors:  Heiko Koller; Volker Kammermeier; Dietmar Ulbricht; Allan Assuncao; Stefan Karolus; Boris van den Berg; Ulrich Holz
Journal:  Eur Spine J       Date:  2006-04-08       Impact factor: 3.134

2.  Biomechanical advantage of C1 pedicle screws over C1 lateral mass screws: a cadaveric study.

Authors:  Florian Fensky; Rebecca A Kueny; Kay Sellenschloh; Klaus Püschel; Michael M Morlock; Johannes M Rueger; Wolfgang Lehmann; Gerd Huber; Nils Hansen-Algenstaedt
Journal:  Eur Spine J       Date:  2013-12-31       Impact factor: 3.134

3.  Evaluation of biomechanical properties of anterior atlantoaxial transarticular locking plate system using three-dimensional finite element analysis.

Authors:  Xian-hua Cai; Zhi-chao Liu; Yang Yu; Mei-chao Zhang; Wei-bing Huang
Journal:  Eur Spine J       Date:  2013-07-03       Impact factor: 3.134

4.  Preclinical evaluation of a novel anterior non-fusion fixation device for atlantoaxial instability: an in vivo comparison study in a canine model.

Authors:  Xuan Cai; Xiaoqing Yi; Haopeng Li; Xijing He
Journal:  Eur Spine J       Date:  2019-02-13       Impact factor: 3.134

5.  Imaging findings of flexion type of hangman's fracture; an attempt for a more objective evaluation with newly introduced scoring system.

Authors:  Sawsan Taif; Venugopal K Menon; Asif Alrawi; Ahmed S Alnuaimi; Kishore K Mollahalli; Khalifa Al Ghafri
Journal:  Br J Radiol       Date:  2016-11-25       Impact factor: 3.039

6.  Motion preservation in type II odontoid fractures using temporary pedicle screw fixation: a preliminary study.

Authors:  Bin Han; Fangcai Li; Gang Chen; Hao Li; Qixin Chen
Journal:  Eur Spine J       Date:  2014-12-28       Impact factor: 3.134

7.  Posterior atalntoaxial fusion with c1 lateral mass screw and c2 pedicle screw supplemented with miniplate fixation for interlaminar fusion : a preliminary report.

Authors:  Sang-Mok Yoon; Jin-Wook Baek; Dae-Hyun Kim
Journal:  J Korean Neurosurg Soc       Date:  2012-08-31

8.  Biomechanical comparison of pedicle screws versus spinous process screws in C2 vertebra: A cadaveric study.

Authors:  Guan-Yi Liu; Lu Mao; Rong-Ming Xu; Wei-Hu Ma
Journal:  Indian J Orthop       Date:  2014-11       Impact factor: 1.251

9.  Design a novel integrated screw for minimally invasive atlantoaxial anterior transarticular screw fixation: a finite element analysis.

Authors:  Yingkai Zhang; Cheng Li; Lei Li; Yanyan Sun; Zeqing Li; Yunli Mei; Xinyuan Feng
Journal:  J Orthop Surg Res       Date:  2020-07-06       Impact factor: 2.359

10.  One-stage posterior C2 and C3 pedicle screw fixation or combined anterior C2-C3 fusion for the treatment of unstable hangman's fracture.

Authors:  Jingchen Liu; Ye Li; Yuntao Wu
Journal:  Exp Ther Med       Date:  2013-01-16       Impact factor: 2.447

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.