Literature DB >> 15026605

An extensible software-based platform for reconstruction and evaluation of CT images.

Dirk-Alexander Sennst1, Marc Kachelriess, Christianne Leidecker, Bernhard Schmidt, Oliver Watzke, Willi A Kalender.   

Abstract

A collection of software applications dedicated to clinical x-ray computed tomography (CT) has been developed. These tools are designed for routine and scientific work and represent a complete platform, which is called syngo Explorer. The user can reconstruct, process, and view CT images in a personal computer environment independently of specialized hardware. To manage patient data and to allow full database access, the system uses the syngo platform (Siemens Medical Solutions, Erlangen, Germany), which serves as a framework for the management and visualization of Digital Imaging and Communications in Medicine (DICOM) images. Part of the philosophy behind syngo Explorer is to quickly provide specialized solutions and to be able to respond to user requests at once. Thus, syngo Explorer was built by choosing a modular setup that comprises standard and specific reconstruction algorithms as well as various artifact reduction techniques; it also helps one attain better insights into dose issues. Various raw data formats of commercial CT scanners are supported. Reconstruction algorithms equivalent to those on the manufacturer's scanner console are provided. A non-syngo Windows XP (Microsoft, Redmond, Wash) version of the application is available. Copyright RSNA, 2004

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15026605     DOI: 10.1148/rg.242035119

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  7 in total

1.  Clinical evaluation of a newly developed method for avoiding artifacts caused by dental fillings on X-ray CT.

Authors:  Yasuo Nakae; Kiyoshi Sakamoto; Takahiro Minamoto; Toshiko Kamakura; Yuji Ogata; Mitsuhiro Matsumoto; Takeshi Johkou
Journal:  Radiol Phys Technol       Date:  2007-12-14

Review 2.  Database application of digital medical X-rays and labs: computerization, storage, retrieval, interpretation, and distribution.

Authors:  Myron Hatcher; Hossein Tabriziani; Irene Heetebry
Journal:  J Med Syst       Date:  2005-08       Impact factor: 4.460

3.  Strategies to configure image analysis algorithms for clinical usage.

Authors:  Thomas M Lehmann; Jörg Bredno
Journal:  J Am Med Inform Assoc       Date:  2005-05-19       Impact factor: 4.497

4.  Validation of CT dose-reduction simulation.

Authors:  Parinaz Massoumzadeh; Steven Don; Charles F Hildebolt; Kyongtae T Bae; Bruce R Whiting
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

5.  Evaluation of a metal artifact reduction algorithm applied to post-interventional flat detector CT in comparison to pre-treatment CT in patients with acute subarachnoid haemorrhage.

Authors:  Angelika Mennecke; Stanislav Svergun; Bernhard Scholz; Kevin Royalty; Arnd Dörfler; Tobias Struffert
Journal:  Eur Radiol       Date:  2016-04-16       Impact factor: 5.315

6.  Multimodal visualization interface for data management, self-learning and data presentation.

Authors:  S Van Sint Jan; X Demondion; G Clapworthy; S Louryan; M Rooze; A Cotten; M Viceconti
Journal:  Surg Radiol Anat       Date:  2006-09-02       Impact factor: 1.246

7.  Spinal fusion-hardware construct: Basic concepts and imaging review.

Authors:  Mohamed Ragab Nouh
Journal:  World J Radiol       Date:  2012-05-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.