Literature DB >> 15020361

Influence of the characteristic curve on the clinical image quality of lumbar spine and chest radiographs.

A Tingberg1, C Herrmann, B Lanhede, A Almén, M Sandborg, G McVey, S Mattsson, W Panzer, J Besjakov, L G Månsson, S Kheddache, G Alm Carlsson, D R Dance, U Tylén, M Zankl.   

Abstract

The "European Guidelines on Quality Criteria for Diagnostic Radiographic Images" do not address the choice of the film characteristic (H&amp;D) curve, which is an important parameter for the description of a radiographic screen-film system. The image contrast of clinical lumbar spine and chest radiographs was altered by digital image processing techniques, simulating images with different H&amp;D curves, both steeper and flatter than the original. The manipulated images were printed on film for evaluation. Seven experienced radiologists evaluated the clinical image quality by analysing the fulfilment of the European Image Criteria (ICS) and by visual grading analysis (VGA) of in total 224 lumbar spine and 360 chest images. A parallel study of the effect of the H&amp;D curve has also been made using a theoretical model. The contrast (DeltaOD) of relevant anatomical details was calculated, using a Monte Carlo simulation-model of the complete imaging system including a 3D voxel phantom of a patient. Correlations between the calculated contrast and the radiologists' assessment by VGA were sought. The results of the radiologists' assessment show that the quality in selected regions of lumbar spine and chest images can be significantly improved by the use of films with a steeper H&amp;D curve compared with the standard latitude film. Significant (p<0.05) correlations were found between the VGA results and the calculations of the contrast of transverse processes and trabecular details in the lumbar spine vertebrae, and with the contrast of blood vessels in the retrocardiac area of the chest.

Entities:  

Mesh:

Year:  2004        PMID: 15020361     DOI: 10.1259/bjr/22642890

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  6 in total

1.  Enhanced visualization methods for computed radiography images.

Authors:  Cristian Bonciu; Mahmoud R Rezaee; Warren Edwards
Journal:  J Digit Imaging       Date:  2006-06       Impact factor: 4.056

2.  Comparison of visual grading and free-response ROC analyses for assessment of image-processing algorithms in digital mammography.

Authors:  F Zanca; C Van Ongeval; F Claus; J Jacobs; R Oyen; H Bosmans
Journal:  Br J Radiol       Date:  2012-07-27       Impact factor: 3.039

3.  Correlation of the clinical and physical image quality in chest radiography for average adults with a computed radiography imaging system.

Authors:  C S Moore; T J Wood; A W Beavis; J R Saunderson
Journal:  Br J Radiol       Date:  2013-04-08       Impact factor: 3.039

4.  Use of a digitally reconstructed radiograph-based computer simulation for the optimisation of chest radiographic techniques for computed radiography imaging systems.

Authors:  C S Moore; G Avery; S Balcam; L Needler; A Swift; A W Beavis; J R Saunderson
Journal:  Br J Radiol       Date:  2012-01-17       Impact factor: 3.039

5.  Investigating the use of an antiscatter grid in chest radiography for average adults with a computed radiography imaging system.

Authors:  C S Moore; T J Wood; G Avery; S Balcam; L Needler; A Smith; J R Saunderson; A W Beavis
Journal:  Br J Radiol       Date:  2015-01-09       Impact factor: 3.039

6.  Intervariability in radiographic parameters and general evaluation of a low-dose fluoroscopic technique in patients with idiopathic scoliosis.

Authors:  Christian Wong; Jens Adriansen; Jytte Jeppsen; Andreas Balslev-Clausen
Journal:  Acta Radiol Open       Date:  2021-09-25
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.