Literature DB >> 1501164

Use of a scanning laser three-dimensional digitizer to evaluate dimensional accuracy of dental impression materials.

D C Quick1, J R Holtan, G K Ross.   

Abstract

A steel die was machined to represent a dental arch with teeth prepared for complete crowns. Impressions and casts were made from the die, and critical dimensions were measured by two methods--one using micrometers and the other a scanning laser three-dimensional (3-D) digitizer. The digitizer recorded measurements were more precise than the micrometer's and virtually eliminated operator error because the acquisition of data was automatic. The digitizer could also be useful for high-precision analyses of the dimensional accuracy of dental impression materials, but the cost and complexity of the instrument makes it less desirable for low-precision work.

Mesh:

Substances:

Year:  1992        PMID: 1501164     DOI: 10.1016/0022-3913(92)90319-6

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  5 in total

1.  Roughness of enamel surfaces after different bonding and debonding procedures : An in vitro study.

Authors:  Lorenz M Brauchli; Eva-Maria Baumgartner; Judith Ball; Andrea Wichelhaus
Journal:  J Orofac Orthop       Date:  2011-03-11       Impact factor: 1.938

2.  Comparison of the accuracy of digitally fabricated polyurethane model and conventional gypsum model.

Authors:  So-Yeun Kim; So-Hyoun Lee; Seong-Keun Cho; Chang-Mo Jeong; Young-Chan Jeon; Mi-Jung Yun; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2014-02-14       Impact factor: 1.904

3.  Comparative evaluation of dimensional stability of impression materials from developing countries and developed countries after disinfection with different immersion disinfectant systems and ultraviolet chamber.

Authors:  Rupandeep Kaur Samra; Shreenivas Vasant Bhide
Journal:  Saudi Dent J       Date:  2017-12-13

4.  Investigation of the effects of storage time on the dimensional accuracy of impression materials using cone beam computed tomography.

Authors:  Murat Alkurt; Zeynep Yeşıl Duymus; Numan Dedeoglu
Journal:  J Adv Prosthodont       Date:  2016-10-21       Impact factor: 1.904

5.  Dimensional stability of two impression materials after a 6-month storage period.

Authors:  Francisco Martins; Patrícia Branco; José Reis; Ignacio Barbero Navarro; Paulo Maurício
Journal:  Acta Biomater Odontol Scand       Date:  2017-11-14
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.