Literature DB >> 15008229

Tooth-supported telescopic crown-retained dentures: an up to 9-year retrospective clinical follow-up study.

Tor Widbom1, Liselott Löfquist, Christin Widbom, Björn Söderfeldt, Mats Kronström.   

Abstract

PURPOSE: This study evaluated outcome and quality of treatments with telescopic crown-retained dentures.
MATERIALS AND METHODS: A total of 72 subjects (27 men and 45 women; mean age 67 years) wearing 75 telescopic crown-retained dentures (18 in the mandible and 57 in the maxilla) participated in the study. There were a total of 368 abutment teeth, 272 in the maxilla and 96 in the mandible. Each patient was clinically examined. Using the CDA evaluation system, four calibrated evaluators also examined, independently, the inner crowns for margin integrity and the superstructure for retention, occlusion, stability, wear, and esthetic appearance. Observer consistency was measured with Cohen's kappa.
RESULTS: The observation period varied from 9 months to 9.3 years (mean 3.8 years). One telescopic crown-retained denture was lost, and 24 abutment teeth (7%) were extracted during the observation period. In 49 abutment teeth (13%), technical complications had occurred, and a total of four framework fractures (5%) were observed. Based on the CDA criteria, most of the characteristics were evaluated as satisfactory. The characteristics "condition of denture-supporting soft tissue" and "superstructure wear" showed the highest frequencies of not acceptable ratings, 44% and 45%, respectively.
CONCLUSION: In this retrospective follow-up study, satisfactory outcome was found for tooth-supported telescopic crown-retained dentures over a mean observation period of 3.8 years.

Entities:  

Mesh:

Year:  2004        PMID: 15008229

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  10 in total

1.  Telescopic retainers for removable partial dentures.

Authors:  S H Gupta; M Viswambaran; R Vijayakumar
Journal:  Med J Armed Forces India       Date:  2015-06-29

2.  Survival rate of removable partial dentures with complete arch reconstruction using double crowns: a retrospective study.

Authors:  Koichi Yoshino; Koji Ito; Masahiko Kuroda; Naoki Sugihara
Journal:  Clin Oral Investig       Date:  2019-07-27       Impact factor: 3.573

3.  Long-term behavior of double crown retained dentures with metal and metal-free secondary crowns and frameworks made of Vectris(©) on all-ceramic primary crowns: a prospective, randomized clinical trial up to 14 years.

Authors:  T Zahn; B Zahn; S Janko; P Weigl; S Gerhardt-Szép; H C Lauer
Journal:  Clin Oral Investig       Date:  2015-09-23       Impact factor: 3.573

4.  Clinical success of implant-supported and tooth-implant-supported double crown-retained dentures.

Authors:  Gunda Bernhart; Andreas Koob; Marc Schmitter; Olaf Gabbert; Thomas Stober; Peter Rammelsberg
Journal:  Clin Oral Investig       Date:  2011-07-26       Impact factor: 3.573

5.  Full mouth rehabilitation of a patient with extracoronal attachments and telescopic prosthesis - a case report.

Authors:  Revathy Gounder; P Laxman Rao; G Ajay Kumar; Githanjali M; N Chandrasekhar
Journal:  J Clin Diagn Res       Date:  2014-10-20

6.  Electroplated and cast double crown-retained removable dental prostheses: 6-year results from a randomized clinical trial.

Authors:  Thomas Stober; Justo Lorenzo Bermejo; Anne-Christiane Séché; Franziska Lehmann; Peter Rammelsberg; Wolfgang Bömicke
Journal:  Clin Oral Investig       Date:  2014-10-11       Impact factor: 3.573

7.  Comparison of retention forces with various fabrication methods and materials in double crowns.

Authors:  Melahat Çelik Güven; Meral Tuna; Ergun Bozdağ; Gizem Nur Öztürk; Gulsen Bayraktar
Journal:  J Adv Prosthodont       Date:  2017-08-16       Impact factor: 1.904

8.  Clinical outcomes of rigid and non-rigid telescopic double-crown-retained removable dental prostheses: An analytical review.

Authors:  Jeong-Gyo Seo; Jin-Hyun Cho
Journal:  J Adv Prosthodont       Date:  2020-02-20       Impact factor: 1.904

9.  Non-Precious Metal Alloy Double Crown-Retained Removable Partial Dentures: A Cross-Sectional In Vivo Investigation.

Authors:  Malin Strasding; Samir Abou-Ayash; Thomas Laziok; Sam Doerken; Ralf-Joachim Kohal; Sebastian Berthold Maximilian Patzelt
Journal:  Materials (Basel)       Date:  2022-09-04       Impact factor: 3.748

Review 10.  Telescopic Denture.

Authors:  Mohammad Ayham Hakkoum; Ghassan Wazir
Journal:  Open Dent J       Date:  2018-03-30
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.