Literature DB >> 15005311

EIT reconstruction algorithms: pitfalls, challenges and recent developments.

William R B Lionheart1.   

Abstract

We review developments, issues and challenges in electrical impedance tomography (EIT) for the 4th Conference on Biomedical Applications of Electrical Impedance Tomography, held at Manchester in 2003. We focus on the necessity for three-dimensional data collection and reconstruction, efficient solution of the forward problem, and both present and future reconstruction algorithms. We also suggest common pitfalls or 'inverse crimes' to avoid.

Mesh:

Year:  2004        PMID: 15005311     DOI: 10.1088/0967-3334/25/1/021

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  47 in total

1.  A fast time-difference inverse solver for 3D EIT with application to lung imaging.

Authors:  Ashkan Javaherian; Manuchehr Soleimani; Knut Moeller
Journal:  Med Biol Eng Comput       Date:  2016-01-06       Impact factor: 2.602

2.  A 3D reconstruction algorithm for EIT using a handheld probe for breast cancer detection.

Authors:  Tzu-Jen Kao; D Isaacson; J C Newell; G J Saulnier
Journal:  Physiol Meas       Date:  2006-04-18       Impact factor: 2.833

3.  Noninvasive pulmonary artery pressure monitoring by EIT: a model-based feasibility study.

Authors:  Martin Proença; Fabian Braun; Josep Solà; Jean-Philippe Thiran; Mathieu Lemay
Journal:  Med Biol Eng Comput       Date:  2016-09-17       Impact factor: 2.602

4.  Toward Electrical Impedance Tomography Coupled Ultrasound Imaging for Assessing Muscle Health.

Authors:  Ethan K Murphy; Joseph Skinner; Maria Martucci; Seward B Rutkove; Ryan J Halter
Journal:  IEEE Trans Med Imaging       Date:  2018-12-10       Impact factor: 10.048

5.  A DIRECT RECONSTRUCTION ALGORITHM FOR THE ANISOTROPIC INVERSE CONDUCTIVITY PROBLEM BASED ON CALDERÓN'S METHOD IN THE PLANE.

Authors:  Rashmi Murthy; Yi-Hsuan Lin; Kwancheol Shin; Jennifer L Mueller
Journal:  Inverse Probl       Date:  2020-12-03       Impact factor: 2.407

6.  Adaptive techniques in electrical impedance tomography reconstruction.

Authors:  Taoran Li; David Isaacson; Jonathan C Newell; Gary J Saulnier
Journal:  Physiol Meas       Date:  2014-05-20       Impact factor: 2.833

7.  Phantom Studies of Fused-Data TREIT Using Only Biopsy-Probe Electrodes.

Authors:  Ethan K Murphy; Xiaotian Wu; Alicia C Everitt; Ryan J Halter
Journal:  IEEE Trans Med Imaging       Date:  2020-10-28       Impact factor: 10.048

8.  Comparative study of separation between ex vivo prostatic malignant and benign tissue using electrical impedance spectroscopy and electrical impedance tomography.

Authors:  Ethan K Murphy; Aditya Mahara; Shadab Khan; Elias S Hyams; Alan R Schned; Jason Pettus; Ryan J Halter
Journal:  Physiol Meas       Date:  2017-03-10       Impact factor: 2.833

9.  Ventilation/Perfusion Relationships and Gas Exchange: Measurement Approaches.

Authors:  Susan R Hopkins
Journal:  Compr Physiol       Date:  2020-07-08       Impact factor: 9.090

10.  Near infrared optical tomography using NIRFAST: Algorithm for numerical model and image reconstruction.

Authors:  Hamid Dehghani; Matthew E Eames; Phaneendra K Yalavarthy; Scott C Davis; Subhadra Srinivasan; Colin M Carpenter; Brian W Pogue; Keith D Paulsen
Journal:  Commun Numer Methods Eng       Date:  2008-08-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.