Literature DB >> 15000622

Figures of merit for detectors in digital radiography. II. Finite number of secondaries and structured backgrounds.

Angel R Pineda1, Harrison H Barrett.   

Abstract

The current paradigm for evaluating detectors in digital radiography relies on Fourier methods. Fourier methods rely on a shift-invariant and statistically stationary description of the imaging system. The theoretical justification for the use of Fourier methods is based on a uniform background fluence and an infinite detector. In practice, the background fluence is not uniform and detector size is finite. We study the effect of stochastic blurring and structured backgrounds on the correlation between Fourier-based figures of merit and Hotelling detectability. A stochastic model of the blurring leads to behavior similar to what is observed by adding electronic noise to the deterministic blurring model. Background structure does away with the shift invariance. Anatomical variation makes the covariance matrix of the data less amenable to Fourier methods by introducing long-range correlations. It is desirable to have figures of merit that can account for all the sources of variation, some of which are not stationary. For such cases, we show that the commonly used figures of merit based on the discrete Fourier transform can provide an inaccurate estimate of Hotelling detectability.

Mesh:

Year:  2004        PMID: 15000622     DOI: 10.1118/1.1631427

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Beyond noise power in 3D computed tomography: the local NPS and off-diagonal elements of the Fourier domain covariance matrix.

Authors:  Angel R Pineda; Daniel J Tward; Antonio Gonzalez; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

2.  A practical exposure-equivalent metric for instrumentation noise in x-ray imaging systems.

Authors:  G K Yadava; A T Kuhls-Gilcrist; S Rudin; V K Patel; K R Hoffmann; D R Bednarek
Journal:  Phys Med Biol       Date:  2008-08-22       Impact factor: 3.609

3.  Assessment of a fluorescence-enhanced optical imaging system using the Hotelling observer.

Authors:  Amit K Sahu; Amit Joshi; Matthew A Kupinski; Eva M Sevick-Muraca
Journal:  Opt Express       Date:  2006-08-21       Impact factor: 3.894

4.  Implementation of a channelized Hotelling observer model to assess image quality of x-ray angiography systems.

Authors:  Christopher P Favazza; Kenneth A Fetterly; Nicholas J Hangiandreou; Shuai Leng; Beth A Schueler
Journal:  J Med Imaging (Bellingham)       Date:  2015-03-25
  4 in total