Literature DB >> 14998544

A novel nib-like design for microfabricated nanospray tips.

Séverine Le Gac1, Cécile Cren-Olivé, Christian Rolando, Steve Arscott.   

Abstract

We present here novel tips for nanoelectrosray ionization-mass spectrometry (ESI-MS) applications. These ionization sources have a planar geometry in the shape of a nib. Their functioning is based on a principle much akin to that of a fountain pen in that fluids are actuated by capillarity. Once a voltage is applied, an electrospray is formed at the nib tip. The nib fabrication relies on micromachining techniques using the epoxy-based negative photoresist SU-8 and a double exposure photolithographic process. Two types of nib-like sources were fabricated; they were made either conductive by metallization with a nickel layer or non-conductive but hydrophilic by covering them with a SiO(2) layer. In the latter case, the HV was applied via a Pt wire inserted into the reservoir feature of the nib. The nib-like sources were tested on an ion trap mass spectrometer using Gramicidin S samples at concentrations as low as 1 microM and ionization voltages as low as 1.2 kV. We have observed a good overall stability of the spray during the tests with no marked decrease in the signal intensity even under extreme conditions.

Entities:  

Year:  2004        PMID: 14998544     DOI: 10.1016/j.jasms.2003.11.001

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  11 in total

1.  A micromachined chip-based electrospray source for mass spectrometry.

Authors:  L Licklider; X Q Wang; A Desai; Y C Tai; T D Lee
Journal:  Anal Chem       Date:  2000-01-15       Impact factor: 6.986

2.  Miniaturized multichannel electrospray ionization emitters on poly(dimethylsiloxane) microfluidic devices.

Authors:  J S Kim; D R Knapp
Journal:  Electrophoresis       Date:  2001-10       Impact factor: 3.535

3.  A fully integrated monolithic microchip electrospray device for mass spectrometry

Authors: 
Journal:  Anal Chem       Date:  2000-09-01       Impact factor: 6.986

4.  An electrospray ionization source for integration with microfluidics.

Authors:  Jun Kameoka; Reid Orth; Bojan Ilic; David Czaplewski; Tim Wachs; H G Craighead
Journal:  Anal Chem       Date:  2002-11-15       Impact factor: 6.986

5.  Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: when does ESI turn into nano-ESI?

Authors:  Andrea Schmidt; Michael Karas; Thomas Dülcks
Journal:  J Am Soc Mass Spectrom       Date:  2003-05       Impact factor: 3.109

6.  Analysis of peptides using partial (no discharge) atmospheric pressure chemical ionization conditions with ion trap mass spectrometry.

Authors:  Simone Cristoni; Luigi Rossi Bernardi; Ida Biunno; Federico Guidugli
Journal:  Rapid Commun Mass Spectrom       Date:  2002       Impact factor: 2.419

7.  Thin-chip microspray system for high-performance Fourier-transform ion-cyclotron resonance mass spectrometry of biopolymers.

Authors:  Joël S Rossier; Nikolay Youhnovski; Niels Lion; Eugen Damoc; Susanne Becker; Frédéric Reymond; Hubert H Girault; Michael Przybylski
Journal:  Angew Chem Int Ed Engl       Date:  2003-01-03       Impact factor: 15.336

8.  Analytical properties of the nanoelectrospray ion source.

Authors:  M Wilm; M Mann
Journal:  Anal Chem       Date:  1996-01-01       Impact factor: 6.986

9.  Characterization of micromachined hollow tips for two-dimensional nanoelectrospray mass spectrometry.

Authors:  Johan Sjödahl; Jessica Melin; Patrick Griss; Asa Emmer; Göran Stemme; Johan Roeraade
Journal:  Rapid Commun Mass Spectrom       Date:  2003       Impact factor: 2.419

10.  Microfabricated PDMS multichannel emitter for electrospray ionization mass spectrometry.

Authors:  J S Kim; D R Knapp
Journal:  J Am Soc Mass Spectrom       Date:  2001-04       Impact factor: 3.262

View more
  2 in total

1.  An open design microfabricated nib-like nanoelectrospray emitter tip on a conducting silicon substrate for the application of the ionization voltage.

Authors:  Séverine Le Gac; Christian Rolando; Steve Arscott
Journal:  J Am Soc Mass Spectrom       Date:  2005-12-15       Impact factor: 3.109

2.  Multinozzle emitter arrays for nanoelectrospray mass spectrometry.

Authors:  Pan Mao; Hung-Ta Wang; Peidong Yang; Daojing Wang
Journal:  Anal Chem       Date:  2011-07-05       Impact factor: 6.986

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.