Literature DB >> 14997101

Loss of flexion after radial head replacement.

John P Birkedal1, D Nicole Deal, David S Ruch.   

Abstract

Prosthetic radial head replacement is a well-documented procedure; however, loss of elbow flexion after radial head arthroplasty has only recently been reported. This study reviews 6 patients who received modular prosthetic radial heads and had a clinically significant decrease in elbow flexion. The implant was removed in 4 of these patients because of reduced elbow motion and pain. This clinical finding is correlated with biomechanical data obtained by use of matched-pair, fresh-frozen upper extremity specimens loaded to 330 N with the forearm in positions of neutral, pronation, and supination for each of three elbow positions (0 degrees, 90 degrees, and 135 degrees). The radiocapitellar gap was monitored and was significantly smaller under load during elbow flexion compared with extension. This study indicates the need for verification of the radiocapitellar gap throughout elbow range of motion in order to prevent these complications.

Entities:  

Mesh:

Year:  2004        PMID: 14997101     DOI: 10.1016/j.jse.2003.11.007

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  17 in total

1.  Is a silastic radial head still a reasonable option?

Authors:  Yariv Maghen; Andrew J Leo; Jennifer W Hsu; Michael R Hausman
Journal:  Clin Orthop Relat Res       Date:  2011-04       Impact factor: 4.176

2.  [Endoprosthetics of the radial column after trauma].

Authors:  M C Müller; T Kälicke; C Burger; O Weber
Journal:  Unfallchirurg       Date:  2010-12       Impact factor: 1.000

3.  Can ulnar variance be used to detect overstuffing after radial head arthroplasty?

Authors:  Jun-Gyu Moon; Jin-Ho Hong; Nitin Bither; Won-Yong Shon
Journal:  Clin Orthop Relat Res       Date:  2013-09-13       Impact factor: 4.176

4.  Simple overlay device for determining radial head and neck height.

Authors:  Jun-Gyu Moon; Richard D Southgate; James S Fitzsimmons; Shawn W O'Driscoll
Journal:  Skeletal Radiol       Date:  2010-03-01       Impact factor: 2.199

5.  Anthropometric study of the proximal radius: does radial head implant fit in all cases?

Authors:  Soo Hwan Kang; Dong Yeop Kim; Hyunwoo Park; Hyun Seok Song
Journal:  Int Orthop       Date:  2015-05-10       Impact factor: 3.075

Review 6.  [Primary radial head arthroplasty in trauma : Complications].

Authors:  K Schmidt-Horlohé; S Buschbeck; D Wincheringer; M Weißenberger; R Hoffmann
Journal:  Orthopade       Date:  2016-10       Impact factor: 1.087

7.  CORR Insights®: High Risk of Further Surgery After Radial Head Replacement for Unstable Fractures: Longer-term Outcomes at a Minimum Follow-up of 8 Years.

Authors:  David Ring
Journal:  Clin Orthop Relat Res       Date:  2019-11       Impact factor: 4.176

8.  Radial head replacement for acute complex fractures: what are the rate and risks factors for revision or removal?

Authors:  Andrew D Duckworth; Neil R Wickramasinghe; Nicholas D Clement; Charles M Court-Brown; Margaret M McQueen
Journal:  Clin Orthop Relat Res       Date:  2014-07       Impact factor: 4.176

9.  Fixation versus replacement of radial head in terrible triad: is there a difference in elbow stability and prognosis?

Authors:  Tyler Steven Watters; Grant E Garrigues; David Ring; David S Ruch
Journal:  Clin Orthop Relat Res       Date:  2014-07       Impact factor: 4.176

10.  Analysis of Radial Head Implant Length with Use of Contralateral Elbow Radiographs.

Authors:  George S Athwal; Dominique M Rouleau; Joy C MacDermid; Graham J W King
Journal:  JBJS Essent Surg Tech       Date:  2012-03-28
View more